10
H
e
a
t
e
r
F-Room Cooling Fan Motor
R-Room Cooling Fan Motor
Comp Cooling Fan Motor
Fresh Island Fan Motor
Fresh Island DAMPER
Ice Maker Geared Motor
Dispenser Geared Motor
Ice Maker Auger Motor
Ice Maker
Dispenser Micro S/W
F-Room Lamp
R-Room Lamp
Dispenser Lamp
Convertible
Door S/W
Power Cord
Earth Screw
Trans
Main S/W
Water tank Heater
Model Name
F- Defrost Heater
F- Drain Heater
F - SUB Drain Heater
R- Defrost Heater
R -Drain Heater
Dispenser Heater
Water Supply Heater
AC 115V 300W(Sheath heater)
AC 115V 35W(Cord Heater)
AC 115V 10W(Cord Heater)
AC 115V 110W(Heater Pipe)
AC 115V 30W(Cord Heater)
On upon F-Defrost
On upon R-Defrost
F-Defrost Heater Overheat Protection Bimetal
R-Defrost Heater Overheat Protection Bimetal
Noise Filter
Electr
ic Components
RF
48SS
AC 115V 7W
(Cordheater)
Model Name
On Temp
Off Temp
Overload
Protector
AC 250V 10A 50/60 HZ
4TM445 PHBYY-82
156
℉
±
48
℉
(
69
±
9
℃)
257
℉
±
41
℉
(
125
±
5
℃)
DC12V DREP3030LB /
φ
67, L237.4, Blower Fan
DC12V DREP3030LB /
φ
67, L295.5, Blower Fan
DC12V DRCP3030LA /
φ
170, Shroud Fan
DC12V G8015S12B-SS / 1800 RPM
DC12V NSBY001TB1 / Unipolar 1-2 Phase Excitation Method
AC 120V / MVCC18AR19 / 0.3 RPM, 4.5W, 8 POLE
AC 120V / MVCC18AR19 / 18 RPM, 3.5W, 8 POLE
110~12V, 60Hz/ISG3240SSI/18RPM,102W
DC 12V NTGN001TA1 / 160 DEG
0.6A / -125VDC / 0.3A-250VDC
Halogen Lamp AC 12V, 35W X 2EA, Reflector 2EA
Halogen Lamp AC12V, 35W X 2EA, Standard30w 1EA
Incandescent Lamp AC 120V, 15W, Blue color
High Brightness LED
※
5EA
AC 125~250V, 11A
AC 125V 15A, AWG #
BSBN (Brass Screw)
AC 250V X 2EA
AC 250V 15A
AC 115V 5W
AC 115V 5W
(Cordheater)
AC 125V 10A / AC 250V 5A
BRANDSOURCE-SM(EN)
2007.1.23
10:31
AM
페이지10
Summary of Contents for RF48SS
Page 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Page 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Page 21: ...22 Door Handle Fridge Door ...
Page 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Page 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Page 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Page 58: ...59 5 When the alarm sound will not turn off ...
Page 59: ...60 ...
Page 60: ...61 6 When there is fault in the display and communication error ...
Page 61: ...62 7 When Fan does not operate ...
Page 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Page 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Page 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Page 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Page 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Page 69: ...70 9 WIRING DIAGRAM ...