35
Communication Error between door Panel <->Main
0.5 sec all on/0.5 sec all off
Communication Error between Main <->Load
0.5 sec all on/0.5 sec all off
None
Proceed until the communication error is corrected.
“Communication Error between door Panel <->Main”
h
as
priority over “Communication Error between Main <-> Load.”
8) Self-Diagnosis Function
①
Self--Diagnosis with Initial Power On
1) With power on,MICOM checks the temperature sensors for errors in a second.
2) A defective sensor is found by self-diagnosis,relevant display LED segments willfalsh on and off at intervals of 0.5 sec. there will be
no beep sound .Even though sensor has a defect,the system will operate emergency mode.
3) When display LED segments are blinking with
defective
sensors found,it only recognizes the self-diagnosis button (Press POWER
REF. and POWER REF. buttons for 8 sec.) normal temp control will be on hold.
4) After self-diagnosis error,when the faulty sensor is repaired or when the POWER FRE. and the POWER REF. buttons are
pressed for 8 sec,the initial self diagnosis will be canceled.
②
Self--Diagnosis during normal operation
1) When pressing the POWER FRE. button and the POWER REF. simultaneously for
6 sec during normal operation,the entire temperature setting display will blink for 2sec at the interval of 0.5 sec then when pressing
the POWER FRE. button and the POWER REF. but t on simultaneously f or 8 sec i ncluding 2 sec bl i nking,self-diagnosis
will be selected.
2) At this point,the sound goes off and the refrigerator goes into the self-diagnosis.
3) When the self-diagnosis starts,the entire LEDs turn off and the error related LED segments blink indicating errors.(See the Self-
Diagnosis Checklist below)
4) When an error occurs,it will be displayed for 30 seconds and then restored to the normal status regardless of its fault.
5) During the self-diagnosis,button selectlons will not be recognized.
③
MICOM Communication Error
1) If any communication error between door Panel
↔
Main MICOM is maintained for 10 seconds with the power on,the refrigerator is
converted to Communication Error Display mode.
2) Then,the entire display panel blinks at the interval of 0.5 sec on and 0.5 sec off until the error is corrected.
3) When a communication error occurs between Main
↔
Load after normal operation, the communication between door Panel
↔
Main MICOM with the initial power on,Main MICOM immediately sends the error message between Main
↔
Load to the door
Panel,and the Panel MICOM immediately goes into the Main
↔
Load Communication Display mode.
4)Then,the entire display panel blinks at the interval of 0.5 sec on and 0.5 sec off until the error is corrected.
Category
Display Options
Button Recognition
Display Range
Display Priority
Press for 8 seconds simultaneously
QUICK ICE
BRANDSOURCE-SM(EN)
2007.1.23
10:31
AM
페이지35
Summary of Contents for RF48SS
Page 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Page 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Page 21: ...22 Door Handle Fridge Door ...
Page 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Page 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Page 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Page 58: ...59 5 When the alarm sound will not turn off ...
Page 59: ...60 ...
Page 60: ...61 6 When there is fault in the display and communication error ...
Page 61: ...62 7 When Fan does not operate ...
Page 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Page 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Page 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Page 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Page 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Page 69: ...70 9 WIRING DIAGRAM ...