16
TROUBLE ShOOTiNG
ProblEM
PossIblE CaUsE
CorrECTIoN
Ice cubes are sticking
together.
1. Ice consumption is low.
Use the ice in the bin frequently. Ice will stick together if
left in insulated bin over long periods of time.
2. Room temperature is too
warm.
Move the unit to an area where temperature is below 90
degrees F.
Ice level is too high.
1. The ice maker is not level.
Use a level to check the unit for level from side to side
and front to rear.
2. Room temperature is too
warm.
Move the unit to an area where temperature is below 90
degrees F.
3. Ice deflector is not in place
or secured properly.
Check to see that the ice deflector is in place and secured
below the grid-cutter.
4. Bin level sensing tube
needs adjusting.
You can adjust the bin level sensing tube by simply
pressing directly down on the tube 5 inches from the
front of the tube to get a desired bin level.
Ice level is too low.
1. The ice maker is not level.
Use a level to check the unit for level from side to side
and front to rear.
2. Room temperature is too
cold.
Move the unit to an area where temperature is above 55
degrees F.
3. The selector switch is not in
the “ON” position.
Set the rocker switch on the grill of the ice maker to the
“ON” position.
Water keeps backing
up into the ice bin
(gravity drain).
1. Inadequate drain system.
Restriction or improperly installed drain lines will cause
water to back up into the ice bin. Make certain there are
no kinks or restrictions in the drain lines. If necessary,
consult a qualified plumber.
2. Foreign material in ice bin
drain.
Foreign material is restricting or blocking the ice bin
drain located at the right rear corner of the ice bin. The
drain will need to be cleared.
Water keeps backing
up into the ice bin
(drain pump).
1. Drain pump tubing kinked
or restricted.
Check inlet, discharge, and vent line tubing for any kinks
or restrictions and repair as necessary.
2. Inlet screen to the drain
pump is restricted or blocked.
Check the inlet screen to the drain pump.
3. Drain pump and/or the ice
maker are not level.
Check and level, if necessary, the drain pump as well as
the ice maker.
The drain pump
cycles on and off
erratically.
1. Vent line to the drain pump
is restricted or kinked.
Check the vent line for any restrictions or kinks and repair
as necessary.
2. Discharge line is restricted
or kinked.
Check the discharge line and connection to the desired
drain for any restrictions or kinks and repair as necessary.
3. The drain pump is not level.
The drain pump must be level. Check for level on the
top of the drain pump case and adjust the tubing or use
shims to level.
Summary of Contents for RF15I
Page 1: ...ICE Maker Use and Care and Installation Guide models RF15I ...
Page 2: ......
Page 7: ...5 PARTS IDENTIFICATION Fig 02 ...
Page 22: ...20 NOTES ...
Page 23: ...Maker À GLAÇONS Manuel d utilisation d entretien et d installation modèlEs RF15I ...