INTERLOCK WITH MEMORY FEATURE 

 

INTERLOCK WITH OTHER OPERATORS:   (REQUIRES THE K1 RELAY OPTION) 

 

VERSIONS 5.20 OR GREATER NOW HAVE THE ABILITY TO ALLOW THE MEGA-ARM TO MONITOR FOR THE FULL OPEN 
POSITION OF A SLIDE, SWING, VERTICAL PIVOT, ROLL UP OR OVERHEAD OPERATOR AS WELL AS THE DOWN POSITION 
OF MOTORIZED TRAFFIC TEETH (MTC-31) AND RAISE THE ARM ONCE FULLY OPEN. 

 

This new feature will allow a logical interface between the MEGA ARM barrier gate and a swing, slide, etc... gate operator (or MTC-31). 
All that is required is 4 wires between the Mega Arm barrier gate and the other operator. It will be necessary to have one set of 
dedicated/isolated dry contacts-{C. & N.C.} COMMON & NORMALLY CLOSED be available at the other operators OPEN LIMIT 
SWITCH. Most units will require that this EXTRA limit switch be added to their open limit switch assembly.  

OPERATION

: A one second pulse from access control device to the MEGA ARM will energize its K1 relay sending an open signal to 

the other operator causing it to open, however,  the MEGA ARM's boom will not raise yet.  When the other operator reaches its full open 
limit switch, this will open the COMMON & NORMALLY CLOSED contact on the EXTRA open limit switch. This will allow the original 
signal from your access control device (that was stored in memory) to now raise the gate arm. As long as the other operator is in the full 
open position, any additional open pulse sent will in turn energize the MEGA ARM's K1 relay to send another open signal to the other 
operator as well as cause the arm to raise again if it has closed via a car crossing the MEGA ARM's close loop. 

 

WIRING

:  Run  2 wires from the other operators  isolated  common & normally closed  contacts of its open limit switch to the MEGA 

ARM  J5#8  and one of the commons J5 , #9-12. Next run 2 wires from the MEGA ARMs K1 relay (common & normally open) to the 
other operators common and open input. (WARNING: max of 30 VOLTS @ .5 AMPS THROUGH RELAY). J5  #8 was the unused 
SHADOW LOOP input on the MEGA ARM. Note: A separate open device (24 hour timer, toggle switch) can be run to the other operator 
to control it without raising the gate arm. Tampering with the other operators safety loops, safety edges and reverse sensors 

WILL NOT

 

cause the arm to raise if one tripped. The arm will only raise if an intended open signal was sent to the MEGA ARM. 
 
NOTE: FOR MOTORIZED TEETH, VERTICAL PIVOT OR OVERHEAD OPERATOR, LEAVE S1-6, S1-8 OFF (THIS WILL KEEP THE 
K1  RELAY 

LATCHED

 UNTIL THE ARM REACHES THE DOWN POSITION. THIS WILL KEEP THE OTHER GATE OPERATOR 

LOCKED OPEN

    OR  TEETH 

LOCKED DOWN

 UNTIL THE ARM CLOSES COMPLETELY). NOTE: IN THIS MODE IF THE ARM 

SENSES AN IMPACT, THE K1  RELAY WILL STAY ENERGIZED HOLDING 

OPEN

  (OR TEETH DOWN) THE OTHER OPERATOR 

UNTIL THE ARM TIMES OUT AND CLOSES. 

 
 

           

MEGA ARM

OTHER OPERATOR

ACCESS
DEVICE

OPEN INPUT

C

N.O.

J5 #1
J5 #12

J5 #8

J5 #11

C

NC

EXTRA OPEN LIMIT

SWITCH

K1 RELAY

(slide/swing/teeth/etc...)

 

S1, 6 &8 (ON) = K1 RELAY PULSE ONLY.  S1, 6 & 8 (OFF) = K1 RELAY LATCH ONLY. 

 

INTER-LOCK  TWO MEGA ARMS WITH "MEMORY":   REQUIRES THE K1 RELAY OPTION 

NOTE: (5.20 or greater) can be used when you have two entry gates that you want to 

INTER-LOCK

 with each other. This is when you 

can only have 

ONE

 gate raised at a time (bottle neck or gates at a cross street). In this case, which ever one raises first will get first 

priority, while if the other gets an open signal, it will be 

HELD IN MEMORY

, then raise once the first gate closes. This will work  if either 

gate has a telephone entry unit or access device (AVI ,prox , etc...).  Connect the K1  relay C & N.O. of each gate to the SHADOW 
LOOP J5 #8 input & common of the other . (Leave S1-6 & 8  OFF to allow relay to stay latched). 

MEGA ARM

TELE-ENTRY

C.

N.O.

J5 #1

J5 #8

J5 #11

C.

N.O.

K1 RELAY

MEGA ARM

J5 #8

K1 RELAY

J5 #11

J5 #9

READER, ETC.

J5 #1
J5 #9 

VISITOR LANE

RESIDENT LANE

 PAGE 14

       

 

Summary of Contents for MEGA ARM

Page 1: ... COVERS THE NEW INTER LOCK MEMORY FEATURES WARNING CHILDREN SHOULD NEVER BE ALLOWED TO PLAY NEAR OR OPERATE AUTOMATIC GATES FAILURE TO OBSERVE SAFE OPERATING PROCEDURE TRAIN YOUR CUSTOMER PROPERLY OR INSTALL PROPER WARNING SIGNAGE MAY RESULT IN SERIOUS INJURY DC SOLUTIONS INC 590 SAWGRASS CORPORATE PARKWAY SUNRISE FLORIDA 33325 PHONE 954 846 9488 FAX 954 846 9464 MEGA ARM MEGA PULSE MEGA SENSE MEG...

Page 2: ...1 S2 MODE SELECTIONS S1 5 MODE SELECTIONS S2 5 CLOSE TIMER SELECTION S2 5 ADJUSTMENTS INSTANT REVERSE DEVICE IRD 6 GATE ARM LEVELING 6 TROUBLE SHOOTING AND MAINTENANCE PROCEDURES BATTERY CHECK OUT 7 GATE NOT OPERATING 7 GENERAL SERVICE 7 SHEAR PIN REPLACEMENT 6 SAMPLE CONFIGURATIONS FREE EXIT OPERATION 8 ENTRY WITH ACCESS CONTROL DEVICE 8 DUAL DIRECTION 8 INTERLOCK MEGA ARMS OR WITH OTHER OPERATOR...

Page 3: ...tch dog reset timer State of the art MOSFET motor drive technology NO contactors or relays Dynamic motor braking to preserve arm positioning Soft start and stop in open and close travel motions No limit switches to fail uses magnetic Hall Effect sensors to monitor arm position Maximum Run Timer for motor MRT with anti tamper protection in closing direction Each unit configurable as master or slave...

Page 4: ... external control devices must have normally open dry contacts DO NOT CONNECT ANY DEVICE WHICH WOULD DELIVER ANY VOLTAGE OF ANY KIND TO THESE TERMINALS Terminals 9 10 11 12 are the commons 0 VDC used to activate the following inputs 1 2 3 OPEN These inputs will trigger gate open when pulsed or hold gate open with maintained contact When released gate will close if closing timer is on or if close i...

Page 5: ...iver RELAY OUTPUT K1 OPTION S1 6 off S1 8 off relay will fire latch when gate is not closed S1 6 on S1 8 off relay will fire when arm is pushed up off of limit switch use with slip clutch option and fires relay when a tail gate is detected by the close loop ANTI TAIL GATE ALARM S1 6 off S1 8 on relay will pulse relay when arm reaches full open position S1 6 on S1 8 on relay will only pulse when in...

Page 6: ...ster gate J5 terminal 12 to slave gate J5 terminal 12 EXAMPLE If only open and close are used at master then three wires will run between gates 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 MASTER J5 SLAVE J5 OPEN CLOSE COMMON EXAMPLE STEP 3 If it is required that if one gate senses an obstruction the other reverses also then 3 additional wires must be run between the master J3 and slave J...

Page 7: ... the obstruction sensor has reversed and re opened the arm or if the S2 7 timer to close is turned on The default will keep the gate up for 4 seconds to allow the vehicle to be moved from the gate arm path Changing settings 1 5 will increase or decrease this hold open time The default of 3 ON and 1 2 4 5 OFF will provide a 4 second close time delay SECONDS 1 2 4 8 16 S2 1 2 3 4 5 6 7 8 SHOWS DEFAU...

Page 8: ...ed this can be done through adjustment to the magnetic cam arm Note that during these adjustments the arm only travels approximately 85 to 89 degrees for its full motion Always adjust for a level arm in the HORIZONTAL POSITION There is a small set screw in the side of the cam arm which can be loosened to allow the cam arm magnet to reach the close limit sensor located on back of controller H2 earl...

Page 9: ...ts are wired correctly test S 3 manual open switch GATE DEAD NO OPERATION 1 Check LED D14 for AC power indication and check AC power switch is on 2 Check LED D11 for Heart Beat pulses if none and D14 AC D5 Brake are on then gate has repeatedly sensed obstructions Clear obstruction then clear with next new input 3 IRD D2 LED is flashing MRT has expired H1 H2 Hall sensors and clearance to magnet on ...

Page 10: ...E LOOP GATE WILL STOP ITS CLOSING MOTION UNTIL LOOP IS CLEARED AGAIN DUAL DIRECTION IS A COMBONATION OF BOTH OF THE ABOVE CONFIGURATIONS TO PROVIDE THE ABILITY FOR TRAFFIC TO ENTER OR EXIT IN THE SAME LANE TERMINAL 7 IS BACKAWAY FREE EXIT TERMINAL 6 IS CLOSE INPUT TERMINAL 6 IS CLOSE INPUT TERMINAL 1 2 3 ARE OPEN INPUTS BACK AWAY LOOP FREE EXIT BACK AWAY LOOP FREE EXIT CLOSE LOOP SPACE BETWEEN LOO...

Page 11: ...F4 F3 IRD AND MRT U3 OVER DRIVE CPU 1 C 2 NC 3 NO 4 24VDC REGULATED TX BLK RED YEL YEL BLU ORG Q3 Q4 Q5 Q6 RELAY OPTIONAL MODE 5 8 I O INTERFACE PORT 24VDC REQULATED 1 AMP DC F1 J5 ACCESSORY POWER IS 24VDC REGULATED RATED AT 500 ma 1 2 AMP POWER AT ACCESSORY AND AT RELAY PIN 4 IS FUSED AT F1 WITH A 1 AMP FAST BLO FUSE NOTE J5 8 IS NOW THE INTERLOCK WITH MEMORY INPUT SEE PAGE 13 D11 HEART BEAT SHOW...

Page 12: ...1 MAGNET 12 MA 012 CAM ARM 13 MA 013 SHEAR PIN 14 MA 014 BOLT NUT 4 MOTOR 15 MA 015 TRANSFORMER 110 220 VAC 24VAC 16 MA 016 MAIN POWER CONNECTION BOX 17 MA 017 BOLT NUT 4 REDUCER 18 MA 018 GROMMET 2 19 MA 019 117 VAC ON OFF SWITCH MA 020 UNIT COVER MA 021 NYLON ARM NUTS 2 MA 022 ARM BOLTS 2 MA 023 GATE ARM 12 FT 20 MA 036 COLLAR 21 MA 037 NYLON WASHER PARTS NOT SHOWN PARTS SHIPPED 1 MEGA ARM OPERA...

Page 13: ...HE STEPS ABOVE THE CAM ARM WHICH ADJUSTS THE LIMITING POINTS OF THE ARMS TRAVEL MUST BE TURNED 90 DEGREES TO THE LEFT WHEN VIEWED WHILE STANDING IN FRONT OF THE CONTROL BOARD CAM ARM NOW POINTS IN THE DIRECTION OF THE ARM AND IS LEVEL WITH MOUNT BRACKET NOTE THE SMALL LIMIT SENSORS ON THE BACK OF THE PCB STEP 4 NOW CHECK TO MAKE SURE THAT S1 7 IS ON MOTOR WIRES ARE REVERSED THE CAM IS ADJUSTED AND...

Page 14: ...INCHES 41 5 17 5 20 25 15 75 41 5 8 0 20 25 13 5 9 0 4 21 5 3 5 3 5 3 5 FOOT PRINT OF BASE ON PAD 9 0 34 75 36 5 8 0 INSIDE POST 5 5 5 5 5 PAD 24x24 6 0 3 25 12 0 12 0 THESE DIMENSIONS WILL CENTER THE OPERATOR ON THE PAD CENTER LINE 2 0 8 0 PAGE 12 ...

Page 15: ...MENSIONS MEASURMENTS ARE IN INCHES 42 0 3 5 FOOT PRINT OF BASE ON PAD 36 5 PAD 24x24X24 SIDE VIEW 14 20 42 0 13 50 13 50 24 0 24 0 DOOR 10 25 8 25 OPEN AREA IN BASE GATE ARM BRACKET 7 125 7 125 14 20 13 50 FOR CONDUIT 12 20 9 90 3 50 PAGE 13 ...

Page 16: ...es from the MEGA ARMs K1 relay common normally open to the other operators common and open input WARNING max of 30 VOLTS 5 AMPS THROUGH RELAY J5 8 was the unused SHADOW LOOP input on the MEGA ARM Note A separate open device 24 hour timer toggle switch can be run to the other operator to control it without raising the gate arm Tampering with the other operators safety loops safety edges and reverse...

Page 17: ... suitable for a particular purpose In no event shall DC Solutions inc be held liable for direct indirect incidental special consequential damages or loss of profits whether based on contract tort or any other legal theory during the course of the warranty or at any time there after The installer and or end user agree to assume all responsibility for all liability in use of this product releasing D...

Reviews: