background image

 

 

 

 

 

Diagram 2:  Range of standard models and accessories
 

Summary of Contents for AM Series

Page 1: ...ION The fan convector serial number model description figure number size are displayed on a label found on the inside of the heater access panel If specified a stencil reference may also be marked on...

Page 2: ...2 Diagram 2 Range of standard models and accessories...

Page 3: ...stats All models Standard or tamper resistant room thermostats with an accelerator heater can be provided for on off and speed change Low temperature cut out LTC thermostat A low temperature cut out t...

Page 4: ...e structure to which heaters are to be fixed must be fit for purpose and capable of accepting plugs and screws anchor bolts or drop rods Floor models require a level base Floor and wall models require...

Page 5: ...onnections on page 6 7 Wire up as detailed in Electrical Connections and Controls on page 7 8 If supplied fit the adjustable type 2 low temperature cut out thermostat to the LTHW flow pipe 9 After fil...

Page 6: ...22mm plain copper tails Local isolating and regulating valves are recommended Observe the correct flow and return positions to ensure the rated heat output see Diagram 7 Fill the system and check for...

Page 7: ...und COMMISSIONING General 1 Purge air from the coil using the manual or automatic air vent or through the mains above the coil if applicable Balance the water flow rate through the system to accepted...

Page 8: ...re safe low voltage of 10VDC or less Diagram 9 Fan speed interface with 3 speeds ECM fan motor option only Size Low speed Medium speed High speed Fan voltage VDC Airflow l s Running current A SFP W l...

Page 9: ...9 Diagram 12 Typical installation detail for Models 15 and 41...

Page 10: ...10 Diagram 13 Typical installation detail for model 17...

Page 11: ...11 Diagram 14 Typical installation detail for models 19 22 53 and 88...

Page 12: ...12 Diagram 15 Typical installation detail for model 21...

Page 13: ...13 Diagram 16 Typical installation detail for models 23 and 92...

Page 14: ...14 Diagram 17 Fixing detail for loose grille and fixing frame Diagram 18 Fixing detail for plinth...

Page 15: ...15 Diagram 19 Fixing detail for suspension brackets wall and ceiling mounted units...

Page 16: ...rmal air flow All accessible surfaces can be wiped with a dry cloth Maintenance 1 Coil Purge any air from the coil using the manual air vent using a suitable key or by turning the knurled thumbwheel o...