38
VIO S218F
Cod. 420120416 REV. 1.0
3. CONNECTIONS
CONNECTING AND LINKING THE POWER SUPPLY
CONNECTING AND LINKING THE AUDIO SIGNAL
The illustration above shows an example of a generic connection. Use cables with powerCON TRUE1® connectors
(only one power cable is provided in the package).
•
Connect the power supply to subwoofer 1 (FULL-RANGE MAINS INPUT)
•
Link the power supply from subwoofer 1 to subwoofer 2 by connecting the output (MAINS LINK) on
subwoofer 1 to the input (FULL-RANGE MAINS INPUT) on subwoofer 2 (link cable not provided)
•
Repeat this step to connect up to the maximum permitted number of subwoofers (see the
chapter)
When connecting the audio signal, connect the sound source to the subwoofer “Input” first. To link another
subwoofer, connect a balanced XLR cable from the “Link” output on the first subwoofer to the “Input” on the
second one, and so on.
PPU
USSH
H
VIO S218
VIO S218F
(flyable)
PPU
USSH
H
PPU
USSH
H
Data Out
Data In
R
RD
DN
Neett
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED
IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input
Link
USB Data Service
Status
Mute
Delay [ms]
Cardioid preset
Polarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0
.0
-6
dB
60
1
.1
-3
dB
70
2
.2
-2
dB
75
3
.3
-1
dB
80
4
.4
0
dB
85
90
5
.5
6
.6
-24
dB
100
7
.7
-18
dB
110
8
.8
-12
dB
Fullrange
9
.9
-9
dB
180°
0°
Ready
Limiter
PPU
USSH
H
VIO S218
VIO S218F
(flyable)
PPU
USSH
H
PPU
USSH
H
Data Out
Data In
R
RD
DN
Neett
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED
IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input
Link
USB Data Service
Status
Mute
Delay [ms]
Cardioid preset
Polarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0
.0
-6
dB
60
1
.1
-3
dB
70
2
.2
-2
dB
75
3
.3
-1
dB
80
4
.4
0
dB
85
90
5
.5
6
.6
-24
dB
100
7
.7
-18
dB
110
8
.8
-12
dB
Fullrange
9
.9
-9
dB
180°
0°
Ready
Limiter
SUBWOOFER 2
SUBWOOFER 2
SUBWOOFER 1
SUBWOOFER 1
POWE
R SOU
R
CE
A
U
DIO SOU
R
CE
110000--224400V
V~~ 5500--6600H
Hzz
M
MA
AIIN
NSS LLIIN
NK
K
FFU
ULLLL--R
RA
AN
NG
GEE
M
MA
AIIN
NSS IIN
NPPU
UTT
OFF
ON
OFF
ON
222200--224400V
V~~ ((99,,44A
Am
maaxx)) 22115500W
Wm
maaxx
110000--112200V
V~~ ((77,,77A
Am
maaxx)) 888800W
Wm
maaxx
222200--224400V
V~~ 5500--6600H
Hzz 66,,66A
A
110000--112200V
V~~ 5500--6600H
Hzz 1122,,33A
A
MAINS FUSES
(REPLACE FUSES WITH SAME RATINGS)
(REMPLACER FUSIBLES AVEC LE MÊME TYPE)
110000--112200V
V~~ ((TT1100A
A LL 225500V
V~~))
222200--224400V
V~~ ((TT55A
A LL 225500V
V~~))
110000--224400V
V~~ 5500--6600H
Hzz
M
MA
AIIN
NSS LLIIN
NK
K
FFU
ULLLL--R
RA
AN
NG
GEE
M
MA
AIIN
NSS IIN
NPPU
UTT
OFF
ON
OFF
ON
222200--224400V
V~~ ((99,,44A
Am
maaxx)) 22115500W
Wm
maaxx
110000--112200V
V~~ ((77,,77A
Am
maaxx)) 888800W
Wm
maaxx
222200--224400V
V~~ 5500--6600H
Hzz 66,,66A
A
110000--112200V
V~~ 5500--6600H
Hzz 1122,,33A
A
MAINS FUSES
(REPLACE FUSES WITH SAME RATINGS)
(REMPLACER FUSIBLES AVEC LE MÊME TYPE)
110000--112200V
V~~ ((TT1100A
A LL 225500V
V~~))
222200--224400V
V~~ ((TT55A
A LL 225500V
V~~))