5. Operating modes
The Profibus displays support 5 different operating modes, as given below.
Display value „signed integer“
0x21
Function
Description
Characteristic
Byte-No.
2 Bytes output data
0
5. Operating modes
5.1. Operating mode 1
Display of 16 bit signed integer values (-32768…32767).
Configuration values
Output data
Display value High-Byte
Function
Byte-No.
Display value Low-Byte
1
0
Position after decimal point „signed integer“
Position after decimal point (see 7.7)
0x21
0x20
Panel parameter (see 7.6.)
0x21
Function
Description
Characteristic
Byte-No.
2 Bytes output data
2
1 Byte output data
1
2 Bytes output data
0
5.2. Operating mode 2
Display value of 16 bit signed integer values (-32768…32767), with brightness control,
flashing and position after decimal point.
Configuration data
Output data
Display value High-Byte
3
Position after decimal point (see explanations under 7.7)
Panel parameter (see explanations under 7.6.)
Function
Byte-No.
Display value Low-Byte
4
2
0-1