4. Setting up the device
Administrator code / Master code (4-digit number-combination free available),
A.Co
:
With this code all parameters can be re-activated, after
LOC
has been activated under
menu item
run
before. By pushing
[P]
in operation mode for approx. 3 seconds,
CodE
occurs in the display and enables the user to reach all parameters by entering the
A.co
. While leaving the parameterisation under
run,
the parameterisation can be
activated permanently by selection of
ULC.
So that at a renew pushing of
[P]
in
operating mode, no new entering of the code needs to be done.
Activiation / Deactivation of the programming interlock or closing-off of the
parametrisation,
run:
With the navigation keys [
▲
] [
▼
], one can choose between the deactivated key lock
Uloc
(works setting) and the activated key lock
Loc
. Confirm the selection with
[P]
.
After this, the display confirms the settings with
"
- - - - -"
, and automatically switches to
operating mode. If
Loc
was selected, the keyboard is locked. To get back into the
menu level, press
[P]
for 3 seconds in operating mode. Now enter the
CODE
(works
setting
1 2 3 4
) that appears using [
▲
] [
▼
] plus
[P]
to unlock the keyboard.
FAIL
appears if the input is wrong. By pressing
[P]
in operation mode for approx. 3
seconds, the first menu group
adr
appears in the display and thus confirms the
change into parameterisation. It stays activated as long as
ULOC
is entered in menu
group
RUN
, thus the display is set back in standard parameterisation again.
Parameterisation level
Menu level
6