DAYLIFF HPW150 Installation & Operating Manual Download Page 31

7. TERMS OF WARRANTY

ii)   Standard Warranty

General Terms

If  equipment  failure  occurs  in  the  normal  course  of  service  having  been 
competently  installed  and  when  operating  within  its  specified  duty  limits 
warranty will be provided as follows:-

Ÿ

Up  to three  years  - The item  will  be  replaced  or repaired  at  no 
charge.

Ÿ

Over three years, less than ve years - The item will be replaced or 
repaired at a cost to the customer of 50% of the Davis & Shirtliff 
market price.

The warranty on equipment supplied or installed by others is conditional upon 
the  defective  unit 

being  promptly  returned  free  to  a  Davis  &  Shirtliff 

ofce

 and collected thereafter when repaired. No element of site repair is 

included in the warranty and any site attendance costs will be payable in full at 
standard  chargeout  rates.  Also  proof  of  purchase  including  the  purchase 
invoice must be provided for a warranty claim to be considered.

I)   General Liability 

•   In lieu of any warranty, condition or liability implied by law, the liability of 

Dayliff (hereafter called the Distributor) in respect of any defect or failure 
of equipment supplied 

is limited to making good by

 

replacement or 

repair

 

(at  the  Distributors  discretion)  defects  which  under  proper  use 

appear  therein  and  arise  solely  from  faulty  design,  materials  or 
workmanship  within  a  specified  period.  This  period  commences 

immediately  after  the  equipment  has  been  delivered  to  the 
customer

  and  at  its  termination  all  liability  ceases.  Also  the  warranty 

period will be assessed

 

on the basis of the date that the Distributor is 

informed of the failure.

Ÿ

This  warranty  applies  solely  to  equipment  supplied  and 

no  claim  for 

consequential damages,

 however arising, will be entertained. Also the 

warranty specifically excludes defects caused by fair wear and tear, the 
effects  of  careless  handling,  lack  of  maintenance,  faulty  installation, 
incompetence on the part of the equipment user, Acts of God or any other 
cause  beyond  the  Distributors  reasonable  control.  Also,  any  repair  or 
attempt  at  repair  carried  out  by  any  other  party 

invalidates  all 

warranties.

29

Summary of Contents for HPW150

Page 1: ...HPW All in One Heat Pump HPW150 HPW200 300...

Page 2: ...STALLATION 12 5 OPERATION AND MAINTENANCE 25 6 TROUBLE SHOOTING 26 7 TERMS OF WARRANTY 27 Davis Shirtliff Ltd 2023 Contents herein are not warranted 3 EQUIPMENT CONTENTS 4 2 SYMBOLS WARNINGS 1 SPECIFI...

Page 3: ...fficient of Performance COP of up to 0 0 4 16 at 20 C Ambient temp 15 C Water temp and settable hot water 0 temperature of up to 75 C This provides up to 80 power savings compared to conventional elem...

Page 4: ...ING This is a household appliance and necessary protection against electric fault should be provided TECHNICAL SPECIFICATIONS Hot Air Inlet Cold Water Outlet Controller Heat Pump Unit Water Tank Drain...

Page 5: ...must have enough space for installation and maintenance WARNING Ensure that inlet or outlet air ow is not obstructed Keep away from wind and combustible gases WARNING Install on a at surface that can...

Page 6: ...safety and health The maximum outlet water temperature is 60 C Flexible installation is achieved by varying air inlet and outlet duct piping as below Equipment is provided with complete isolation bet...

Page 7: ...h will be recovered Fan Centrifugal fan with three speeds to draw in air Compressor Concentrates and increases heat to form a very hot gas which is passed to the heat exchanger to heat pool water Evap...

Page 8: ...sufficient air circulation The air duct total length should be equal or less than 6 meters and the duct diameter should be equal or more than 150 mm Condensed water outlet Water for domestic use mixin...

Page 9: ...lose inlet valve when water overflows from water outlet Inspect the pipeline and ensure that there is no water leakage When intake pressure is below 1 5 Bar a booster pump may be installed When intake...

Page 10: ...tlet Air inlet Air Outlet Air inlet Air Outlet As a rule heat pumps should be installed outdoors However by varying the design of air intake and outlet ducts the heat pump can be used to condition col...

Page 11: ...he unit should be protected from rain hailstorm and other extreme weather Dimensions mm Straight line pressure drop Pa m Straight line length m Bend pressure drop Pa Bend s quantity Rectangle Duct Oth...

Page 12: ...00 Power Supply Min Cable diameter mm2 Manual Switch A Leakage Protection Device 220V 50Hz 2 5 Size continous length 30m Ground Wire Capacity Fuse 1 0mm 20 20 Below 30mA 0 1 sec Directly connect power...

Page 13: ...11 Electric Wiring Diagram HPW150...

Page 14: ...l Temperature limiter RD BL BL RD RD RD BL Transformer GN GREEN BR BROWN BL BLUE BK BLACK RD RED WH WHITE WIRE COLOR CODE Y YELLOW OR ORENGE Low speed RD N N1 N2 N3 BK BL BL BL Coil temp Ambient temp...

Page 15: ...Water temperature over 50 can cause severe burns instantly or death from scalds Children disabled and elderly are at high risk and must be protected Water temperature limiting valves are recommended D...

Page 16: ...nd setting temperature and also can query the coil temperature ambient temperature exhaust temperature and so on Power cut memory function When power is cut the clock will still work Timing on off Aut...

Page 17: ...nstantly bright Current water temperature in the tank Constantly bright Set water temperature in the tank Constantly bright Current outlet water temperature Constantly bright Current inlet water tempe...

Page 18: ...Press and hold for 3 seconds in the power on off state to enter the query state 3 In the query status press and check status 4 At parameter set status press to modify parameters 3 Down 1 Press at main...

Page 19: ...in the off state Then from the 2nd time the state will be same as last time before power off Set the temperature control mode When the controller is in normal display state press the M key to switch b...

Page 20: ...ime clock settings In the main interface click the button to enter the real time clock setting interface Press the button the hour part of the number will flash press or to set the hour on the clock P...

Page 21: ...g mode speed heating is not allowed The three time slots are as follows 05 00 07 00 16 00 18 00 and 20 00 00 00 When the timing control mode is enabled the corresponding symbols are displayed in the w...

Page 22: ...sidered to be in an untimed return time period throughout the day If the start time of a certain working period is greater than the end time the end time is considered to be the next day The factory d...

Page 23: ...e set temperature the cooling stops Name Remark Code Fluorine cycle water cycle heat pump High pressure switch Low pressure switch Water ow switch EEV Value Evaporator coil sensor Ambient temperature...

Page 24: ...en the controller is in the normal display state click the button to start the manual water circulation function At this time the Back Pump icon flashes The manual return water control is as follows N...

Page 25: ...ackwater pipe temperature return water set temperature return water temperature difference for 5 seconds or temperature control return water time 2 minutes the water pump will turn off The buzzer soun...

Page 26: ...ill lock the protection and the compressor will be locked in the shutdown protection state At this time only the shutdown and restarting can unlock the compressor At this time the electric heater is s...

Page 27: ...65 C it is judged that the outlet water temperature is too high It will shutdown heat pump for protection and when the outlet water temperature is detected to be 60 C the protection is withdrawn Tempe...

Page 28: ...ication indicator of the main control board flashes The buzzer sounds when an alarm occurs Press any key to silence the alarm The fault code table is as follows Error Code Name 01E Water flow switch d...

Page 29: ...pump works a long term and with high efficiency clean inner tank every half a year to remove accumulated sediment observe the following rules while cleaning the inner tank Turn off power supply of he...

Page 30: ...er is damaged Contact Dayliff retailer The circuit board of the i n d i c a t o r l a m p i s damaged The tap water is cut off No output from the hot water outlet The water pressure is too low Wait fo...

Page 31: ...warranty condition or liability implied by law the liability of Dayliff hereafter called the Distributor in respect of any defect or failure of equipment supplied is limited to making good by replacem...