DAYLIFF HPW150 Installation & Operating Manual Download Page 3

Dayliff HPW Heat Pump Hot Water Systems are designed for all domestic water heating 
applications that utilise the high efficiency benefits of heat pump technology. The integral 
systems combine a hot water   storage tank with an efficient heat pump that generates 
heat from ambient air by utilising the natural heat generating phenomenon of the gas 
evaporation/condensation cycle. This is transferred to the stored water by circulation 
through a coil type heat exchanger in the tank. Tank construction is carbon steel with 
internal enamel coating and a magnesium anode is fitted for cathodic protection against 
corrosion.  The  tank  is  lined  with  high  grade  thermal  insulation  for  heat  retention. 
Particular features are:-

0

0

 

•  HPW heat pumps work best under ambient temperature of between -7 C to 43 C

 

•  High quality integral heat pump fitted on top of the hot water cylinder with quiet 

GMCC compressor that provides a Coefficient of Performance (COP) of up to 

0

0

4.16  (at  20 C  Ambient  temp,  15 C  Water  temp)  and  settable  hot  water 

0

temperature of up to 75 C. This provides up to 80% power savings compared to 
conventional element heaters.

 

•  Tube type heat exchanger coiled externally around the water tank for performance 

and safety with inbuilt sterilising function 

 

•  Integral 2kW electric heating element for temperature boosting

 

•  Digital controller for operational and timer settings and fault indication

 

•  Supplied  complete  with  ozone  friendly  R134A  regrigerant  gas  for  optimal 

performance 

Dayliff HPW systems are high efficiency, high performance water heaters and are the ideal 
solution for all residential hot water supply requirements.

Congratulations on selecting a Dayliff Heat Pump Hot Water Systems. 
They  are  manufactured  to  the  highest  standards  and  if  installed  and 
operated  correctly  will  give  many  years  of  efcient  and  trouble  free 
service.  Careful  reading  of  this  Installation  Manual  is  therefore 
important, though should there be any queries they should be referred 
to the equipment supplier.

1. SPECIFICATIONS

HPW150    

HPW200 & 300

Summary of Contents for HPW150

Page 1: ...HPW All in One Heat Pump HPW150 HPW200 300...

Page 2: ...STALLATION 12 5 OPERATION AND MAINTENANCE 25 6 TROUBLE SHOOTING 26 7 TERMS OF WARRANTY 27 Davis Shirtliff Ltd 2023 Contents herein are not warranted 3 EQUIPMENT CONTENTS 4 2 SYMBOLS WARNINGS 1 SPECIFI...

Page 3: ...fficient of Performance COP of up to 0 0 4 16 at 20 C Ambient temp 15 C Water temp and settable hot water 0 temperature of up to 75 C This provides up to 80 power savings compared to conventional elem...

Page 4: ...ING This is a household appliance and necessary protection against electric fault should be provided TECHNICAL SPECIFICATIONS Hot Air Inlet Cold Water Outlet Controller Heat Pump Unit Water Tank Drain...

Page 5: ...must have enough space for installation and maintenance WARNING Ensure that inlet or outlet air ow is not obstructed Keep away from wind and combustible gases WARNING Install on a at surface that can...

Page 6: ...safety and health The maximum outlet water temperature is 60 C Flexible installation is achieved by varying air inlet and outlet duct piping as below Equipment is provided with complete isolation bet...

Page 7: ...h will be recovered Fan Centrifugal fan with three speeds to draw in air Compressor Concentrates and increases heat to form a very hot gas which is passed to the heat exchanger to heat pool water Evap...

Page 8: ...sufficient air circulation The air duct total length should be equal or less than 6 meters and the duct diameter should be equal or more than 150 mm Condensed water outlet Water for domestic use mixin...

Page 9: ...lose inlet valve when water overflows from water outlet Inspect the pipeline and ensure that there is no water leakage When intake pressure is below 1 5 Bar a booster pump may be installed When intake...

Page 10: ...tlet Air inlet Air Outlet Air inlet Air Outlet As a rule heat pumps should be installed outdoors However by varying the design of air intake and outlet ducts the heat pump can be used to condition col...

Page 11: ...he unit should be protected from rain hailstorm and other extreme weather Dimensions mm Straight line pressure drop Pa m Straight line length m Bend pressure drop Pa Bend s quantity Rectangle Duct Oth...

Page 12: ...00 Power Supply Min Cable diameter mm2 Manual Switch A Leakage Protection Device 220V 50Hz 2 5 Size continous length 30m Ground Wire Capacity Fuse 1 0mm 20 20 Below 30mA 0 1 sec Directly connect power...

Page 13: ...11 Electric Wiring Diagram HPW150...

Page 14: ...l Temperature limiter RD BL BL RD RD RD BL Transformer GN GREEN BR BROWN BL BLUE BK BLACK RD RED WH WHITE WIRE COLOR CODE Y YELLOW OR ORENGE Low speed RD N N1 N2 N3 BK BL BL BL Coil temp Ambient temp...

Page 15: ...Water temperature over 50 can cause severe burns instantly or death from scalds Children disabled and elderly are at high risk and must be protected Water temperature limiting valves are recommended D...

Page 16: ...nd setting temperature and also can query the coil temperature ambient temperature exhaust temperature and so on Power cut memory function When power is cut the clock will still work Timing on off Aut...

Page 17: ...nstantly bright Current water temperature in the tank Constantly bright Set water temperature in the tank Constantly bright Current outlet water temperature Constantly bright Current inlet water tempe...

Page 18: ...Press and hold for 3 seconds in the power on off state to enter the query state 3 In the query status press and check status 4 At parameter set status press to modify parameters 3 Down 1 Press at main...

Page 19: ...in the off state Then from the 2nd time the state will be same as last time before power off Set the temperature control mode When the controller is in normal display state press the M key to switch b...

Page 20: ...ime clock settings In the main interface click the button to enter the real time clock setting interface Press the button the hour part of the number will flash press or to set the hour on the clock P...

Page 21: ...g mode speed heating is not allowed The three time slots are as follows 05 00 07 00 16 00 18 00 and 20 00 00 00 When the timing control mode is enabled the corresponding symbols are displayed in the w...

Page 22: ...sidered to be in an untimed return time period throughout the day If the start time of a certain working period is greater than the end time the end time is considered to be the next day The factory d...

Page 23: ...e set temperature the cooling stops Name Remark Code Fluorine cycle water cycle heat pump High pressure switch Low pressure switch Water ow switch EEV Value Evaporator coil sensor Ambient temperature...

Page 24: ...en the controller is in the normal display state click the button to start the manual water circulation function At this time the Back Pump icon flashes The manual return water control is as follows N...

Page 25: ...ackwater pipe temperature return water set temperature return water temperature difference for 5 seconds or temperature control return water time 2 minutes the water pump will turn off The buzzer soun...

Page 26: ...ill lock the protection and the compressor will be locked in the shutdown protection state At this time only the shutdown and restarting can unlock the compressor At this time the electric heater is s...

Page 27: ...65 C it is judged that the outlet water temperature is too high It will shutdown heat pump for protection and when the outlet water temperature is detected to be 60 C the protection is withdrawn Tempe...

Page 28: ...ication indicator of the main control board flashes The buzzer sounds when an alarm occurs Press any key to silence the alarm The fault code table is as follows Error Code Name 01E Water flow switch d...

Page 29: ...pump works a long term and with high efficiency clean inner tank every half a year to remove accumulated sediment observe the following rules while cleaning the inner tank Turn off power supply of he...

Page 30: ...er is damaged Contact Dayliff retailer The circuit board of the i n d i c a t o r l a m p i s damaged The tap water is cut off No output from the hot water outlet The water pressure is too low Wait fo...

Page 31: ...warranty condition or liability implied by law the liability of Dayliff hereafter called the Distributor in respect of any defect or failure of equipment supplied is limited to making good by replacem...

Page 32: ...INSXXXA 00 22...