Timed return water:
•
When the controller is in the normal display state, press and hold the “ ” button for
3 seconds to start or turn off the timed water return function; the “ ” icon lights up
when it is turned on, and the “ ” icon turns off when it is turned off.
The timing return control is as follows:
No return water temperature sensor
When the timing water returned function is activated and the timed start time is reached,
the water pump is started. After 30 seconds, the water pump is turned off, and the buzzer
sounds three times, prompting the user to use the hot water; After 15 minutes, the water
pump is started again and the cycle is repeated.
If press and hold the "cold hot" button for 1 second or the timed return water close time is
reached in this process, the timed water return function will be turned off (the return water
function is still valid for next time, unless the timed return function is turned off).
Return water temperature sensor intalled
When the timing return water starts, and the start time reaches, if the return water pipe
temperature < return water set temperature, and the current water tank temperature ≥
return water set temperature + return water temperature difference, the return water
pump will start.
If backwater pipe temperature ≥ return water set tempe return water temperature
difference for 5 seconds or temperature control return water time ≥ 2 minutes, the water
pump will turn off.
The buzzer sounds three times, prompting the user to use hot water; When the pipe
temperature < return water set temperature, the water return pump is started again and
the cycle is repeated.
If press and hold the "cold hot" button for 1 second or the timed return water close time is
reached in this process, the timed return function will be turned off (the return water
function is still valid for next time, unless the timed return function is turned off).
When the return water temperature is faulty, it will
automatically switch to the “no return water temperature
sensor” mode.
NOTE
Anti-fouling function
Sometimes the return pump/circulation pump stops for a long time, the pump will be
rusted or scaled, and the pump needs to be started periodically.
After the pump has been on standby for 12 hours, it is forced to run for 1 minute.
High temperature sterilization control for Electric heater
Manual sterilization mode:
While the controller is in normal display state, press and hold the “M”+“
∧
”+“
∨
” button for
more than 5 seconds at the same time, the heater symbol flashes to indicate that it enters
the manual sterilization mode.
•
During this process, press and hold the “cold and hot” button for 1 second to
manually cancel the manual water return function.