8
Minimum Voltage
Set by default at -10% .
Modifications to operating limits beyond the default parameters will
i m m e d i a t e l y r e n d e r t h e w a r r a n t y n u l l a n d v o i d .
Maximum Voltage
Set by default at +10% .
Modifications to operating limits beyond the default parameters will
i m m e d i a t e l y r e n d e r t h e w a r r a n t y n u l l a n d v o i d .
DESCRIPTION OF PARAMETER
VALUE
207 (230)
FAULT
360 (400)
-
-
253 (230)
440 (400)
Maximum Current P1 / P2 / P3 / P4
This parameter enables entry of the maximum current for each motor.
Enter the maximum current value, increasing it by 10-15% with respect to the
rated motor value.
Modifications to operating limits beyond the parameters stated on the model
data plate will immediately render the warranty null and void.
Display brightness on standby
This parameter enables entry of the brightness setting applied when the
d i s p l a y s e t s t o s t a n d b y ( w a i t 9 s e c o n d s f o r a p r e v i e w ) .
Time For Entry To Set-up
This parameter enables entry of the time to keep the SETUP button
pressed for access to the set-up menu.
1 - … A
As per order
0-9
3 Sec
4
2 - 30 Sec
5.2 FUNCTION 2 - Draining with level sensors and oats/pressure
switches
This operating mode is used for drainage applications using level sensors and floats or
pressure switches, enabling the control of one or more pumps.
Motor Clicson
Motor 2/ Duty
Float/ Pressure
Switch
Earthing Grounding
Motor Output
Starting Capacitor
(1-phase)
Supply Input
(T for 3-phase)
Alarm Float
Switch
Motor Clicson
Motor 1/ Ex
change
Float/Pressure Switch
Min Level Input
Cumulative Alarm
Output
Earthing Grounding
Motor Output
Supply Input
(T for 3-phase)
Starting Capacitor
(1-phase)