background image

DC

Engine Pumps

Installation & 

Operating Manual

DC80D

DC80P

DCX150P

Summary of Contents for DC80D

Page 1: ...DC Engine Pumps Installation Operating Manual DC80D DC80P DCX150P ...

Page 2: ......

Page 3: ...ECIFICATIONS 1 1 2 SUCTION HOSE CONNECTIONS 3 PUMP OPERATIONS 3 4 ROUTINE MAINTENANCE 4 4 SAFETY WARNINGS 5 5 INDEX Davis Shirtliff Ltd 2015 Contents herein are not warranted TROUBLE SHOOTING 6 6 WARRANTY 7 7 ...

Page 4: ... reading of this instruction manual is therefore extremely important and if you have any queries please refer them to your retailer 3 FLOW m hr 3 FLOW m hr HEAD m HEAD m 0 10 20 30 30 40 20 10 70 60 50 90 50 0 10 20 30 70 60 40 10 5 20 15 35 30 25 80 DC PETROL DIESEL DC 100D DC 80P D DC 50P DC 80K DC 50K 0 3 FLOW m hr HEAD m 0 20 40 120 10 5 20 15 25 140 DCX DCT 50 DCX2 50D DCX1 80D DCX1 50P DCX2 ...

Page 5: ...rs suitable for pumping lightly silted water and a sturdy carrying and protection frame DCX High specification high pressure pump with option of single or twin impeller DCT Robust diesel pumps for pumping polluted water and sewage DCI Cast iron engine pumps for heavy duty dewatering DCI 80D WARNING Note that performance curves relate to the engine governor set at maximum speed to achieve maximum r...

Page 6: ...43 64 Capacity cc Type DC 80D DC 100D Fuel Consumption lt hr 2 1 DC 80K DC 50K Kohler Sh265 Fuel Star ter Petrol Petrol Petrol Petrol Diesel Diesel Ensure the suction hose is of the rigid type and it should be of the same diameter as the pump inlet and fitted with the correct connectors Connect suction hose to the pump as indicated Hose band 1 Coupling 2 Hose nipple 3 Coupling packing WARNING Airt...

Page 7: ...le pump performance it should be limited below 4m Ensure the delivery head is within the performance capacity of the pump see pump curve Priming port 4 ROUTINE MAINTENANCE For Diesel pumps see separate engine manual The below instructions apply to petrol versions only ENGINE OIL Check engine oil daily If low refill with SAE30 Change engine oil after first month or after 20hrs operation and thereaf...

Page 8: ...n is used in case of overhaul Do not use pump on a slope Fuel spillage may occur and cause a fire Keep children away from pump when in operation Avoid proximity to fire when refueling Highly inflammable G a s o li n e Do not operate pump inside a well or pit There will be an exhaust gas build up and the pump will overheat Ensure good ventilation around the pump and do not operate indoors Exhaust g...

Page 9: ...n and adjust plug Carburettor is blocked Spark plug is wet dirty Air cleaner dirty Too much engine oil Insufficient engine oil No fuel 6 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Cannot pull or hard to pull Recoil starter Overhaul Engine Dismantle clean the impeller Rusting inside engine Engine jammed Jammed Impeller Insufficient delivery or no output Check suction hose Air leakage from suc...

Page 10: ...andling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond the Company s reasonable control Also any repair or attempt at repair carried out by any other party invalidates all warranties ii Standard Warranty If equipment failure occurs in the normal course of service having been competently installed and when operating withi...

Page 11: ......

Page 12: ...INS177E 07 15 ...

Reviews: