41
The device can be programmed daily and weekly for radiator heating. With 7 different
time programs, the start and end times of the program, the operating temperature of
the device during program and the ΔT temperature difference can be adjusted. If the
programming has been made and activated, the device will not be heated during
periods of time that are not programmed. Device waits at standby position for heating.
Time program can be active or inactive with
button. When the time program is
active, the current program number is displayed. While the device is in normal
operating position;
Enter setting menu by pressing
button 2-3 seconds
Press
button one second interval until “
Timing Time Phase
” is seen. Timing
program blink.
6.4.9. Time Program Setting