background image

LCD display provides you to see the water temperature that you set. 

When you press the On/Off button you can see the water  flowing, the 

fan  turning, the temperature you set and the occurrence of the flame 

on the LCD display.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UKDAX 

– 11ST  MODEL 

 

 

 

 

 

 

 

 

 

 

 

2. THE CONFIGURATION OF YOUR WATER HEATER . 

The  fuel  expenses  are  reduced  in  low  water 

temperatures as your device can operate in the 

desired constant water temperatures.  

By  the  automatic  water  controlled  on/off 

system,  when  the  water  valve  is  opened,  the 

water  heater  will  be  ignite  automatically  and 

the hot water flow will be provided.  When the 

water  valve  is  closed,  the  water  flow  will  stop 

and the flame will be off automatically.   

Thanks  to  its  feature  of  operating  with  low 

pressure  water,  it  will  not  be  affected  by  the 

low  water  pressure  that  occurs  in  the  high 

apartment flats. 1 mSS 

The  temperature  control  setting  buttons  make 

for  users  easy  to  obtain  different  water 

temperature that they desire.  

By  the  high  pressure  safety  system,  when  the 

water  pressure  is  higher  than  it’s  needed, 

safety valve will discharge the excess water by 

become a part of a activity. 

 By  the  high  temperature  safety  system,  in 

case the water get hotter than it is needed, the 

gas  will  be  cut  automatically  and  the  damage 

to the water heater will be prevented.  

The  flame  instability  is  prevented  and  the 

Summary of Contents for UKDAX-11ST

Page 1: ......

Page 2: ...o not attempt to operate the device by yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your water heater conforms to the gas type you...

Page 3: ...e safety system in case of the water getting hotter than it is needed the gas will be cut off automatically and the damage of the water heater will be prevented The flame instability is prevented and...

Page 4: ...l be provided When the water valve is closed the water flow will stop and the flame will be off automatically Thanks to its feature of operating with low pressure water it will not be affected by the...

Page 5: ...atural Gas G20 Gas input pressure 30mBar 20mBar Fan Power 36 W Water flow t 25K 11 l min 11 l min Nominal power P 19 15 KW Nominal load Q 22 8KW Gas consumption 2 12 kg h 2 12 kg h Water pressure Min...

Page 6: ...during the repair and maintenance there should be sufficient space around the device for repair and maintenance Flammable and explosive substances must definitely be kept away from the water heater Th...

Page 7: ...waste gas pipe hole according to pipe measurement which is given as follows The waste gas pipes are supplied with the water heater Place the fresh air waste gas pipe into the holes previously opened...

Page 8: ...ges of the bracket part as to face the water heater chimney and the pipe Fill hole opened for the waste gas pipe in the wall with a substance resistant to burning and isolate it Make sure that the iso...

Page 9: ...water leakage There should be a valve in the cold water main pipe line in order to cut the water when needed Connect the hot water flow of the water heater to the hot water pipe of your installation w...

Page 10: ...o C and 65 o C degrees The water temperature you set will show stability after some time according to the distance of the water heater to the tap and the change of the water pressure Turn on the wate...

Page 11: ...re you want to set will increase and when the button is pressed the temperature you want to set will decrease Your water heater has the capacity to heat 11 lt of water per minute If you would like to...

Page 12: ...hen pres SET button to enter injection water rate setting mode Press 12 indicates setting water injection rate is 120 L Shut the gas and water off after using and then in order to shut the water heate...

Page 13: ...nplug anything before the gas leaves out completely Do not forget that any flame or a spark that may occur in such a case will lead to fire or explosion Check the pipes mount the places where happens...

Page 14: ...ou must not disconnect electrical connection and ON OFF buttons on the heater pannel must be ON position At that position your heater will be heat inside water by automatically short time working and...

Page 15: ...ain E3 Windpressure switch failure or blocage in flur duct Clean blockage and impurity of flue duct E4 1 Fan gives error while operate 2 Connection of fan is wrong 1 Change the fan 2 Control the conne...

Page 16: ...until sufficient air comes The wind pressure outside is too much x x Do not use for a certain time Frozen water x Use again after the melting occurs Insufficient water pressure x Control the water pre...

Reviews: