Thanks  to  its  feature  of  digital  constant  water  setting,  the  water 

temperature will remain constant in the degree you set. 

The  fuel  efficiency  is    reduced  in  low  water  temperature  as  your 

device can operate in the desired constant water temperatures.  

By  the  automatic  water  controlled  on/off  system,  when  the  water 

valve is opened, the water heater will be ignite automatically and the 

hot water flow will be provided.  When the water valve is closed, the 

water flow will stop and the flame will be off automatically.   

Thanks  to  its  feature of  operating  with  low  pressure  water,  it  will  not 

be  affected  by  the  low  water  pressure  that  occurs  in  the  high 

apartment flats. 2 mSS 

The  temperature  control  adjustment  buttons  make  for  users  easy  to 

obtain different water temperature that they desire.  

By  the  high  pressure  safety  system,  when  the  water  pressure  is 

higher than it’s needed, safety valve will discharge the excess water 

by become a part of a activity. 

 By the high temperature safety system, in case of  the water getting 

hotter than it is needed, the gas will be cut off automatically and the 

damage of the water heater will be prevented.  

The  flame  instability  is  prevented  and  the  water  is  cooled  after  the 

flame is off with the features of blowing inside the water heater before 

the ignition (air fan blows air for 2~4 seconds before ignition) and the 

blowing  after  service  (air  fan  will  go  on  blowing  air  for  10  seconds 

after the water stops and the flame is off). 

Thanks to the safe and reliable design of the combustion system, the 

air is taken from outside by the fan for the purpose of the combustion 

and it is sent out again after the combustion.  

By  the  system  of  continuous    electronic  ignition,  100%  success  is 

achieved in ignition.  

The device is equipped with the multi-purpose safety system. Even if 

the  power  is  supplied to  the water  heater again  in  power  failure,  fan 

failure,  the  blocking  of  the  waste  gas  pipe  or  strong  reverse  wind 

blowing  the  gas  will  be  automatically  cut  and  the  automatic  ignition 

system will be disabled. In this case the water heater will need to be 

restarted.  

1.  THE  FEATURES  AND  THE  CHARACTERISTICS  OF 

YOUR WATER HEATER  

Summary of Contents for UKDAX-11ST

Page 1: ......

Page 2: ...o not attempt to operate the device by yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your water heater conforms to the gas type you...

Page 3: ...e safety system in case of the water getting hotter than it is needed the gas will be cut off automatically and the damage of the water heater will be prevented The flame instability is prevented and...

Page 4: ...l be provided When the water valve is closed the water flow will stop and the flame will be off automatically Thanks to its feature of operating with low pressure water it will not be affected by the...

Page 5: ...atural Gas G20 Gas input pressure 30mBar 20mBar Fan Power 36 W Water flow t 25K 11 l min 11 l min Nominal power P 19 15 KW Nominal load Q 22 8KW Gas consumption 2 12 kg h 2 12 kg h Water pressure Min...

Page 6: ...during the repair and maintenance there should be sufficient space around the device for repair and maintenance Flammable and explosive substances must definitely be kept away from the water heater Th...

Page 7: ...waste gas pipe hole according to pipe measurement which is given as follows The waste gas pipes are supplied with the water heater Place the fresh air waste gas pipe into the holes previously opened...

Page 8: ...ges of the bracket part as to face the water heater chimney and the pipe Fill hole opened for the waste gas pipe in the wall with a substance resistant to burning and isolate it Make sure that the iso...

Page 9: ...water leakage There should be a valve in the cold water main pipe line in order to cut the water when needed Connect the hot water flow of the water heater to the hot water pipe of your installation w...

Page 10: ...o C and 65 o C degrees The water temperature you set will show stability after some time according to the distance of the water heater to the tap and the change of the water pressure Turn on the wate...

Page 11: ...re you want to set will increase and when the button is pressed the temperature you want to set will decrease Your water heater has the capacity to heat 11 lt of water per minute If you would like to...

Page 12: ...hen pres SET button to enter injection water rate setting mode Press 12 indicates setting water injection rate is 120 L Shut the gas and water off after using and then in order to shut the water heate...

Page 13: ...nplug anything before the gas leaves out completely Do not forget that any flame or a spark that may occur in such a case will lead to fire or explosion Check the pipes mount the places where happens...

Page 14: ...ou must not disconnect electrical connection and ON OFF buttons on the heater pannel must be ON position At that position your heater will be heat inside water by automatically short time working and...

Page 15: ...ain E3 Windpressure switch failure or blocage in flur duct Clean blockage and impurity of flue duct E4 1 Fan gives error while operate 2 Connection of fan is wrong 1 Change the fan 2 Control the conne...

Page 16: ...until sufficient air comes The wind pressure outside is too much x x Do not use for a certain time Frozen water x Use again after the melting occurs Insufficient water pressure x Control the water pre...