While the device reaches to overheat temperature mode, it can be set
temperature difference which is wanted to operate.
While the device is operating regularly,
1. Enter setting menu by pressing button 2-3 seconds.
2. Press to button
is seen,ΔT temperature difference starts to
blink.
3. ΔT temperature difference value is set with
or
buttons.
4. Exit setting menu by pressing
button.
It is possible to control device with room thermostat thus the device is
operate according to ambient temperature which room thermostat
occurs. While the device which will make room thermostat connection is
starting-up by authorized service, room thermostat connection will be
activated from inside of device. After room thermostat connection is
done to the device, it is needed to room thermostat bring into use from
setting menu. Although room thermostat is connected, if it is not brought
into use from setting menu, it is not function. While the room thermostat
is not connected,if it is brought into use, device is continuously stood by
for heating and radiator does not operate. When the device room
thermostat function is set as ON,
is seen.
While the device is operating regularly,
1. Enter setting menu by pressing
button 2-3 seconds.
2. Press button 2 times.
is seen , room thermostat
ON/OFF indicator blinks
6.4.4 MAKING ΔT TEMPERATURE DIFFERENCE SETTING
6.4.5 MAKING ROOM THERMOSTAD SETTING