![daviteq WSSFC-G4F-NH3-8-01 User Manual Download Page 19](http://html1.mh-extra.com/html/daviteq/wssfc-g4f-nh3-8-01/wssfc-g4f-nh3-8-01_user-manual_3846478019.webp)
TIME
ALERT_DURATION
Alert duration in hours
8-bit unsigned integer
Formula: 8-
bit_Alert_duration =
real_TempAlert_duration_in_hours
Range: 0 to 255 hours
Accuracy: 1 hour
Example: 0b00100000 =
0x20 = 32 => 32 hours
8
Tentative
TENTATIVE
Tentative number
8-bit unsigned integer
Formula: (8-bit_Tentativve
+1)= real_tentative #
Range: 1 to 256
Accuracy: 1
Example: 0b00000111 =
0x7=7=> 7+1
=>tentative # 8
8
Size
Event Type
EVENT_ID
HW_VERSION
FW_VERSION
CURRENT
CONFIGURATION
10.0
bits
4
4
8
64
Payload data format
EVENT_ID
HW_VERSION
FW_VERSION
LATEST_SIGFOX_
DOWNLINK
START_UP
yes
yes
yes
yes
Event Type
EVENT_ID
HW_VERSION
FW_VERSION
CURRENT
CONFIGURATION
10.0
bits
4
4
8
64
Payload data format
EVENT_ID
HW_VERSION
FW_VERSION
LATEST_SIGFOX_
DOWNLINK
HEARTBEAT
yes
yes
yes
yes
Event Type
EVENT_ID
HW_VERSION
FW_VERSION
CURRENT
CONFIGURATION
10.0
bits
4
4
8
64
Payload data format
EVENT_ID
HW_VERSION
FW_VERSION
LATEST_SIGFOX_
DOWNLINK
PARAMETERS_UPDATE
yes
yes
yes
yes
Event Type
EVENT_ID
HW_NH3_ERROR
RESERVED
NH3
3.0
bits
4
1
3
16
Payload data format
EVENT_ID
HW_NH3_ERROR
-
NH3
NH3_FORCE_DATA
yes
yes
zeros
yes
Event Type
EVENT_ID
HW_NH3_ERROR
RESERVED
NH3
MIN_NH3
AVG_NH3
MAX_NH3
6.7.2 Sigfox Uplink Frame Format