30001
4
1
2
0-
1000
UINT16
Read
Damping
output, part
per
thousand
length
‰
30002
4
1
2
0-
1000
UINT16
Read
Non
damping
output, part
per
thousand
length
‰
30003
4
1
2
UINT16
Read
Value of C
30004
4
1
2
0-
1000
UINT16
Read
Temperature °C
Div 10
30005
4
1
2
UINT16
Read
FW_version
30006
4
1
2
INT16
Read
Tilt
(difference
in fuel level
per minute)
‰
40007
3
1
2
1-247
30
UINT16
Read/Write Address of
slave
40008
3
1
2
0-1
1
UINT16
Read/Write Baud rate
Baud rate:
0: 9600, 1:
19200
40009
3
1
2
0-2
0
UINT16
Read/Write Parity
Parity: 0:
none, 1:
odd, 2:
even
1. Periodically clean the oil tank 2, 3 or 6 months depending on usage and contamination.
2. Periodically clean the sensor and filter footer 2, 3 or 6 months by:
Cover a sensor's vent before using the air sprayer for another.
Remove and clean the filter footer.
11. Periodic Cleaning Guidance
12. Troubleshooting