Read specifications thoroughly and make sure that its output are suitable to reading devices.
Power supply must be in the permitted range.
Do not take out the label and take off the lid as this will lead to the instability of the sensor and manufacturer
could deny warranty. (except cutting of sensor length within the allowed range).
Make sure all the necessary tools are ready before the installation.
CAP10CNC be equipped with screws. We advise customers should use stainless steel rivets to fasten
the plastic flange onto tank for all type of tanks and only using screws for the thick and hard ones.
Sensor length
standard 1500mm, extend to 4000mm (by extension probe) or cut down to
100mm
Output
4-20mA output (with 250 ohms precision resistor), or RS485/ModbusRTU
Power supply
8..50VDC
Consumption
max 35mA
Working pressure
-1 .. 2 barg
Working temperature
-40 oC .. + 85 oC
Accuracy
+/- 0.1% of span (at 25 oC)
Temperature drift
< + 0.03% of span per 10oC
Resolution
1/1000 of span
Sensor materials
Alloy & Engineering plastic
Electrical connection
connector M12 (matched connector and cable must be ordered seperately)
Housing
Cast alumium, IP67 protection
Process connection
Plastic flange
Standard accessories
flange, o-ring, gasket, protection covers, self-tapping screws, twisted seal
Certification
CE-Marking per EN61236-1 (with test report)
4. Note Before Installation
5. Specification
6. Full Package