- 7 - 

Position 0: no lamp is on, even when the timer is on. 
 
Keep your eyes open during the treatment. You are in the position to read, watch TV or carry out any other 
activities. After every 1 – 2 minutes you should look for a few seconds into the light source. A constant staring into 
the light source must be avoided. After the preset application time has run out, the instrument switches off 
automatically. It is also possible to switch off the instrument by turning the timer to zero 

 
Important:

 In order to be protected against UV-rays, the light box must only be operated with its original 

protective filter in place. 
 

Operation of the  light therapy units with the DAVITON

®

 

The activated DAVITON

®

 (not included) reminds you with an acoustical signal every 90 sec for 3 sec to look into the light 

source. 
 

Mounting the light therapy devices LD 440, LD 880 and LD 1100 on the wall 

 

The light

 

therapy devices

 

Physiolight

 

LD

 

440

the LD

 

880 and

 

the LD

 

1100 can be fastened with screws and dowels on a 

flat wall

 

(a 

distance 

of 505

 

mm for the

 

LD

 

440

a distance of

 

1105

 

mm for the

 

LD

 

880 and

 

a distance of

 

1405

 

mm for the

 

LD

 

1100). 

A sufficient substainability of the wall is necessary.

 

You may

 

have

 

to use

 

special fixings

 

(for example if drywall

 

walls are 

used

). 

The installation has to be

 

carried out by a

 

qualified electrician.

 

Under the

 

device

 

a free space

 

of at least 20

 

cm

 

must 

be left

Plug the female connector

 

of the

 

supplied

 

power supply cable

 

into the

 

connector

located on the right

 

bottom of the 

housing

Insert the male connector

 

into a schuko plug socket

 

Frequency and time of treatment 

If the treatment takes place in a clinic or in the doctor’s surgery it should initially be carried out 5 times per week for a period 
of 2 – 3 weeks; thereafter, 3 times per week for a period of 2 – 3 weeks. After that, the treatment should take place as 
needed or when the symptoms occur again. At home, the treatment can take place daily, especially during autumn and 
winter time. The best treatment time for winter depression is the early morning or the time of the lowest mood. 
 

Side effects and contraindications 

By using phototherapy the following side effects have been observed: Headaches, nausea, irritability and burning of the 
eyes can occur rarely for a short period. In case of porphyria, i.e. a metabolic disorder that is associated with a disturbance 
of  the  formation  of  red  blood  pigment  heme,  it  is  not  allowed  to  treat  with  light  therapy.  Other  contraindications,  i.e., 
circumstances that prohibit the use of light therapy, are not known so far. 
Please take care in case of all types of eye diseases and the eye specialist should be consulted before. In case of patients 
being under treatment with lithium or medicine for example Fluoxetine, Imipramine et al., which increase the sensibility of 
the eyes on light a supervision of the light therapy by an eye specialist could be considered. 
 

Cleaning, maintenance and recycling 

The instruments do not need any special maintenance and requires no calibration. The manufacturer does not require such 
preventive inspections by other persons. Qualified companies / individuals can make repairs to the light therapy devices. 
The  necessary  technical  documents  and  other  information  can  be  requested  by  DAVITA

®

.  The  mains  have  to  be 

disconnected, before opening the devices. To clean the outer casing parts of the devices, we recommend a mild cleaning 
agent (as used for glass).  

 

Packaging: DAVITA

®

 takes part in the system „Grüner Punkt“ („Green Point“). All packaging parts are made out 

of  recyclable  materials  and  must  be  recycled  in  accordance  of  the  guideless  concerning  each  material  (eco-
friendly). The PhysioLight LD 220, LD 440, LD 880 and LD 1100 have a casing out of stainless steel.  
 

Fluorescent lamps as well as instruments marked with the symbol of a crossed out dustbin may not be disposed via the 
regular garbage. The electrical and electronic components must be recycled separately. Please get in touch with your local 
authority to find the right way to of disposal. If electrical appliance is disposed of in landfills or dumps, hazardous substances 

Summary of Contents for PhysioLight LD 1100

Page 1: ...KG IM HAMMEREISEN 29a 47559 KRANENBURG Lichttherapieger te Light therapy boxes Appareils de luminoth rapie PhysioLight LD 220 LD 440 LD 880 LD 1100 DE Gebrauchsanweisung 2 GB User manual 6 FR Mode d e...

Page 2: ...n mit Luft oder mit Sauerstoff oder Lachgas Das Geh use sollte nicht direkt der Sonne ausgesetzt werden Durchf hrung der Lichttherapie mit dem Lichttherapieger t PhysioLight LD 220 Stellen Sie das Ger...

Page 3: ...nden einzusetzen Die Installation ist von einem Elektrofachmann durchzuf hren Unter dem Ger t muss ein freier Raum von mindestens 20 cm verbleiben Stecken Sie die Buchse der beiliegenden Netzanschlus...

Page 4: ...sonen Medizinprodukt gem 93 42 EWG Ja Ja Ja Ja Geh use Qualitativ sehr hochwertiges Edelstahlgeh use Geh usema e H 60 B 40 T 8 cm H 66 B 70 T 10 cm H 66 B 130 T 10 cm H 66 B 160 T 10 cm Gewicht 7 5 kg...

Page 5: ...rmationen Vor N sse sch tzen CE Zeichen gem den notwendigen Anforderungen der Medizinprodukte richtlinie 93 42 EEC Schutzklasse I Hersteller SN Seriennummer Entsorgung Dieses Produkt nicht mit dem nor...

Page 6: ...g free and should not be exposed to sun How to carry out light therapy with the light therapy device PhysioLight LD 220 Place the instrument on an even surface and connect the plug with a wall socket...

Page 7: ...utumn and winter time The best treatment time for winter depression is the early morning or the time of the lowest mood Side effects and contraindications By using phototherapy the following side effe...

Page 8: ...cm distance for 30 minutes 5 000 Lux at 75 cm distance for 60 minutes 5 000 Lux at 100 cm distance for 60 minutes 5 000 Lux at 100 cm distance for 60 minutes 5 000 Lux at 100 cm distance for 60 minute...

Page 9: ...ufacturer SN Serial number DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary EMV Bericht Link www davita de downlo...

Page 10: ...reil n est pas adapt une utilisation proximit de m langes inflammables et an sth siques avec l air de l oxyg ne ou du protoxyde d azote L appareil doit tre libre d acc s et ne pas tre plac directement...

Page 11: ...llez ce que un espace libre de 20 cm minimum soit assur Branchez la fiche secteur une prise femelle de l appareil qui est situ e la droite du bouton du bo tier La prise doit tre par la suite connect e...

Page 12: ...th rapie PhysioLight LD 880 Appareil de luminoth rapie PhysioLight LD 1100 R f 10220 10440 10880 11100 EAN R f 4038962102209 4038962104401 4038962108805 4038962111003 Traitement simultan de 1 personne...

Page 13: ...ionnement continu Marquages et symboles Les symboles suivants apparaissent dans la pr sente notice sur l appareil et sur les accessoires Attention veuillez lire avec attention les documents ci joints...

Reviews: