Wind Speed:
Miles per Hour (mph), Knots (knot), kilometers per Hour (km/hr), or Meters
per Second (m/s)
Rain:
Inches (in) or Millimeters (mm)
After selecting units of measure, select OK.
The Configuration Utility saves your choices. All information is displayed in
the units of measure you selected.
Output Test
Pressing the Output Test button puts the Alarm Output data logger into
Output Test mode. In this mode, all other functions of the data logger cease.
Do not press this button unless you wish to perform a test because it may
disrupt the behavior of your connected electrical device.
This function is used to test the output of the Alarm Output data logger. Push
the button of the output you want to test. The button will be depressed to
indicate Closed circuit mode and raised to indicate Open circuit mode. To
utilize this function effectively, you will need to connect a device to the
appropriate output so that you can tell when it is turning on or off.
You can connect an ohmmeter to the outputs and see if the output changes
state (low for closed or high for open). You may also connect your electrical
device to one or more of the outputs. You can check to see if the unit runs
with the Output circuit closed or fails to run with the Output circuit open.
To leave this mode, simply exit the dialog box by pressing the OK button.