8
Manual
DV-11T II
BLOWER
• Button 2 = Minimum speed regulation of the
BLOWER. Set this to the desired maximum
speed.
• Button 3 = Maximum speed regulation of the
BLOWER. Set this to the desired minimum
speed.
EXHAUSTER
• Button 4 = Minimum speed regulation of the
Exhauster. Set this to the desired maximum
speed.
• Button 5 = Maximum speed regulation of the
Exhauster. Set this to the desired minimum
speed.
1.7 THE FUSE OF THE DV-11T II
The DV-11T II has two glass fuses.
These fuses turn off the DV-11T II automatically
in case of an overload and / or a short circuit.
In case the fuses have turned off the DV-11T II
(during an overload and / or a short circuit),
the DV-11T II can be reset.
Resetting the DV-11T II
• Remove the 230Vac voltage from the DV-11T II.
• Resolve the problem that caused the fuse to
be activated.
• At the inside of the DV-11T II you will see
the clad printed-circuit board with two white
holders in which the glass fuses are placed.
• Remove the glass fuse and insert a new fuse
into the holder
• Close the DV-11T II up carefully.
• The DV-11T II is ready for use again.
1.8 FOR YOUR SAFETY
• The correct operation of the DV-11T II is only
guaranteed, if you observe this manual.
• Although it is possible to install the DV-11T II
yourself, we recommend to have this done by
a certified installer.
• Before installing the DV-11T II, the 220v.
voltage MUST be taken off the power point
(Check this!)
• This guide should only be used for the DV-11T II.
• DAVIN
®
products are covered by a 1-year
warranty.
• To qualify for this warranty, you are required
to return the DV-11T II to the point of sale.
• If changes are made to DAVIN
®
products
without the express and written prior
permission of the manufacturer, the warranty
will become void.
• The DAVIN
®
warranty will also become void
with improper installation of the DV-11T II.
• Neither the manufacturer, nor the importer,
nor the retailers of the DV-11T II are liable for
damages arising from the use of the DV-11T II.
SERVICE NUMBER / HELPDESK:
+31 (0)6 – 14 813 447
DV-11T II Binnenwerk PMS.indd 6
13-6-2012 0:32:41