1.0 GENERAL
The DV-11T II is a thermostatically controlled
ventilation control system for an EXHAUSTER
or BLOWER, with minimum and maximum
regulation for both engines.
1.1 TECHNICAL DATA
Dimensions
: 110 x 210 x 70mm.
Required voltage
: 230 Vac / 50Hz.
Max. Output
: 2 x 1350 watt.
: 2 x 6 Ampère.
Isolation level
: IP-44
1.2 REQUIRED (ACTIVE) VOLTAGE DV-11T II
To connect the DV-11T II you will preferably need
a ‘clean’ group of at least 16 Amp.
A ‘clean’ group means that this group will only
be used by the DV-11T II.
• The DV-11T II needs to be connected directly
to, and near the ‘clean’ group.
• Install, if needed, a grounded outlet onto your
‘clean’ group.
• If you do not have a(n) (extra) ‘clean’ group we
advise you to have a ‘clean’ group installed by
a certified installer.
1.3 THE INSTALLATION OF THE DV-11T II
The DV-11T II should now be mounted.
At the bottom of the DV-11T II are 2 mounting
brackets; these should be pushed out before you
can use them. The DV-11T II can now easily be
placed on a (flat) surface.
1.4 CONNECTING THE DV-11T II TO A ‘CLEAN’
GROUP
• In step 1.2 you have already mounted a
grounded outlet onto your ‘clean’ group.
• Turn the ‘clean’ group ‘OFF’.
• Insert the plug of the DV-11T II into the outlet
of the ‘clean’ group.
1.5 CONNECTING THE ENGINE (EXHAUSTER)
TO THE DV-11T II
In steps 1.2 to 1.4;
• A ‘clean’ group is connected (or we have had it
connected by a certified installer.)
• The DV-11T II has been mounted onto a flat
surface.
• The DV-11T II has been connected to a ‘clean’
group.
Now the engine (of the exhauster) has to be
connected to the DV-11T II.
• Insert the plug of the exhauster into the
mounting socket (the socket) on the side of
the DV-11T II.
• Turn the ‘clean’ group back ‘ON’
• If everything is properly connected, the engine
of the exhauster will start.
1.6 ADJUSTING THE DV-11T II
Everything is now connected. Now the DV-11T II
can be adjusted for use.
The 2 power outlets;
On the LEFT side of the DV-11T II there is an
outlet for the BLOWER.
On the RIGHT side of the DV-11T II there is an
outlet for the Exhauster.
On top of the DV-11T II there are five black
buttons.
• Button 1 = Thermostat
Set this to the desired temperature.
HU
UK
DV-11T II Binnenwerk PMS.indd 5
13-6-2012 0:32:41