Page | 2  

 

 

FD-777A

  

Installation 
Manual

 

 

 

Specifications 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Support 

Service Company:

 To contact David-Link Technical Support department, call 1- 888-755-9418, 

Monday through Friday 9AM to 6PM PST. Questions can also be submitted through our website 
at 

www.davidlinkusa.com

 

End User: 

Please contact your service provider/installer. 

Parameter 

Specification 

Power Votage 

12V 3A 

Environment 

Indoor  

Tempature Tolerance 

22

to 130

 F 

Output Format 

NO/NC, Wiegand 26 

Communication 

TCP/IP, USB Drive 

Motion Detect 

Infrared 

Capture Time 

< 0.4 Sec 

Capture Distance 

15 – 20 Inch 

Camera Type 

2x 1.3 Mega Pixels 

Capture Type 

3D Image 

Installation Mode 

Standalone, Controller 

Note:

 For additional information about installing and programming the FD-777A keypad 

please contact David-Link at 1- 888-755-9418 

Summary of Contents for FD-777

Page 1: ...Page 1 FD 777 FACIAL RECOGNITION INSTALLATION MANUAL For Access Control or Time Attendance ...

Page 2: ...ntact your service provider installer Parameter Specification Power Votage 12V 3A Environment Indoor Tempature Tolerance 22 to 130 F Output Format NO NC Wiegand 26 Communication TCP IP USB Drive Motion Detect Infrared Capture Time 0 4 Sec Capture Distance 15 20 Inch Camera Type 2x 1 3 Mega Pixels Capture Type 3D Image Installation Mode Standalone Controller Note For additional information about in...

Page 3: ...and reader mode Below is a brief explanation of each mode Refer to the programming section for details about selecting each mode Standalone Mode By default the FD 777A is programmed for Standalone Mode In this mode all the users and other programming options are maintained within the reader and no additional controller is required The lock and all other inputs and outputs are connected directly to...

Page 4: ...ure the FD 777A on the mounting plate using the supplied Allen Key screw Communication Port Detail Use the terminal block found in packaging to connect proper wires to the port at the back of the FD 777A reader Securely tighten up the electrical wires on the block before plugin to the port Pin Suggest Wire Color Description GND Black Ground 12V Red 12V DC GND Black Ground KEY Blue Exit Button NC O...

Page 5: ...Page 5 Wiring Sample Standalone Mode Magnetic Lock Wiring Sample Standalone Mode Strike Lock ...

Page 6: ...Page 6 Wiring Sample Wiegand Reader Mode Wiring Sample Open Button Note This is only for using standalone mode If using Wiegand reader mode open button will be connect to the third party controller ...

Reviews: