Precautions 

1.

 

To install this product, installer must have basic drilling and wiring skills. 

2.

 

Shut off all power before attempting any wiring procedures. 

3.

 

DO NOT attempt any internal repairs of the product. All repairs and/or component 
replacements must be performed by a David-Link technician or authorized technician. 
Unauthorized disassembly or repair: 
 

 

May jeopardize personal safety and may expose one to the risk of electrical shock. 

 

May adversely affect the safety and/or reliability performance of the product. 

 

Will void manufacturer’s warranty. 

 

Reader Operating Modes 

The FD-777A reader has two installation modes: 

Standalone Mode

, and 

Wiegand reader mode

Below is a brief explanation of each mode. Refer to the programming section for details about 
selecting each mode. 

 

Standalone Mode: 

By default, the FD-777A is programmed for Standalone Mode. In this mode, all the users 
and other programming options are maintained within the reader and no additional 
controller is required. The lock and all other inputs and outputs are connected directly 
to the FD-777A. 

Wiegand Reader Mode: 

In Wiegand reader mode, a separate third-party Wiegand Access Control panel is 
required. When you register your face on the FD-777A, an enroll ID is required and it is 
then sent to the control panel as Wiegand card data. The control panel maintains the 
users and programming options and makes all the access control decisions. The locking 
device and all inputs and outputs are connected to the third-party control panel. 

 

 

 

 

Summary of Contents for FD-777

Page 1: ...Page 1 FD 777 FACIAL RECOGNITION INSTALLATION MANUAL For Access Control or Time Attendance ...

Page 2: ...ntact your service provider installer Parameter Specification Power Votage 12V 3A Environment Indoor Tempature Tolerance 22 to 130 F Output Format NO NC Wiegand 26 Communication TCP IP USB Drive Motion Detect Infrared Capture Time 0 4 Sec Capture Distance 15 20 Inch Camera Type 2x 1 3 Mega Pixels Capture Type 3D Image Installation Mode Standalone Controller Note For additional information about in...

Page 3: ...and reader mode Below is a brief explanation of each mode Refer to the programming section for details about selecting each mode Standalone Mode By default the FD 777A is programmed for Standalone Mode In this mode all the users and other programming options are maintained within the reader and no additional controller is required The lock and all other inputs and outputs are connected directly to...

Page 4: ...ure the FD 777A on the mounting plate using the supplied Allen Key screw Communication Port Detail Use the terminal block found in packaging to connect proper wires to the port at the back of the FD 777A reader Securely tighten up the electrical wires on the block before plugin to the port Pin Suggest Wire Color Description GND Black Ground 12V Red 12V DC GND Black Ground KEY Blue Exit Button NC O...

Page 5: ...Page 5 Wiring Sample Standalone Mode Magnetic Lock Wiring Sample Standalone Mode Strike Lock ...

Page 6: ...Page 6 Wiring Sample Wiegand Reader Mode Wiring Sample Open Button Note This is only for using standalone mode If using Wiegand reader mode open button will be connect to the third party controller ...