9. WATER PUMP CONTROL CONNECTION
For flexibility there are 3 options of running the water pump when connected to the heat pump via the wiring
diagrams in this instruction.
P0 – Water pump will run continuously when the heat pump is turned on.
P1 – Heat pump and water pump will run until temperature is reached and then shut off.
P2 – Heat pump and water pump will run until temperature is reached and then shut off, the water pump will
restart every hour to see if there is a temperature difference, then either restart the heat pump or go back
into standby.
The default setting is P2. To change these parameters please contact your nearest Davey dealer.
Inverter heat pump solution
I. Water pump control connection
Breaker/fuse
(Customer prepare)
Earthing
Power Supply
230V~/50Hz
Water pump: 230V voltage,
(Customer prepare)
Power Supply
230V~/50Hz
Earthing
connection
Customer remote
control
switch
connector
Breaker/fuse
(Customer prepare)
Water pump: 230V voltage,
≤
500W capacity
Water Pump
Breaker/fuse
(Customer prepare)
Powercord
16
Customer remote
control
switch
connector
Water Pump
(not supplied)
Remote control
switch for use if no
wi-fi connection
(not supplied)