background image

3

1. FOREWARD

The Davey heat pump uses eco-friendly R32 gas and step-less DC inverter technology which allows heat to 

be extracted from the surrounding air more efficiently. This heat is transferred to the pool water by a twisted 

titanium heat exchanger. This method generates substantial energy savings compared to: a conventional 

electric resistance heater, and natural, or propane gas pool heaters. 

2. SAFETY PRECAUTIONS

We have provided important safety messages in this manual and on your heat pump.
Please always read and obey all safety messages.

Environmentally friendly R32 Refrigerant is used for this heat pump.

2.1 Warning

WARNING: Low velocity burning material.

R32 Gas

The WARNING sign denotes a hazard. It calls attention to a procedure, practice, 

or the like, which, if not correctly performed or adhered to, could result in personal 

injury or injury to a third party. These signs are rare, but are extremely important. 

WARNING: Do not use means to accelerate the defrosting process or to clean other than 

those recommended by the manufacturer.
The appliance shall not be stored near any ignition sources (for example; open flames, an 

operating gas appliance or an operating electric heater.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.

R32 Gas

INSTALLATION REMINDERS:
The installation of any pipework should be kept to a minimum.
Pipework should be protected from physical damage and shall not be installed in an 

unventilated place.
The heat pump should not be installed indoor.
Any mechanical connections need to be kept accessible for maintenance purposes.
The heat pump requires 50cm clear space on each side to be clear from obstructions for 

ventilation purposes.
Any maintenace or service needs to be carried out in compliance with national 

gas regulations.

QUALIFICATION OF WORKERS: A technician with a Refrigerant Handling Licence should 

carry out any service or maintenance carried out on the heat pump refrigerant equipment.
A registered electrician should carry out any service or maintenance required for the heat 

pump electrical equipment.

2.2 Attention

a. Please read the following instructions before installation, use and maintenance.
b. Installation must be done by professional staff only in accordance with this manual and any 

local regulations.

c. Leakage test must be performed after installation.
d. Please don’t stack substances, which will block air flow near inlet or outlet area, otherwise the efficiency of 

the heat pump will be reduced or even stopped.

Summary of Contents for DHP130

Page 1: ...Please pass on these instructions to the operator of this equipment Pool Heat Pump Installation and Operating Instructions...

Page 2: ...ANCE 7 4 1 Installation reminder 7 4 2 Wiring 9 4 3 Electric wiring diagram 9 4 4 References for protecting devices and cable specification 9 5 OPERATION GUIDANCE 10 5 1 Key function 10 5 2 Operation...

Page 3: ...appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour R32 Gas INSTALLATION REMINDERS The installation of any pipework should be kept to a...

Page 4: ...r outage happens during operation the heat pump will start when the power is restored c Please switch off the main power supply in lightening and storm weather to prevent from damage caused by lightni...

Page 5: ...ortant to ensure that the flow rate in set to the advised water flow rate in section 3 6 and that the pressure does not exceed 500kPa In accordance with AS NZS 60335 2 40 we are obligated to inform yo...

Page 6: ...0 19 1 38 0 26 1 80 0 33 2 50 0 38 2 90 0 49 3 80 0 65 4 84 Input power at 50 speed kW 0 51 0 7 0 95 1 1 1 44 1 84 Rated input current A 0 83 5 98 1 13 7 83 1 44 10 90 1 66 12 7 2 15 16 53 0 95 7 01...

Page 7: ...his heat through its heat exchanger to the pool water Your Davey heat pump should be installed in a well ventilated area WARNING Improper installation adjustment service maintenance or use can cause f...

Page 8: ...fastened the bracket must be strong enough and antirust treated 2 Please ensure 50cm of clearance around each side of the Davey heat pump or the efficiency of the heat pump will be reduced 3 Although...

Page 9: ...full disconnection of the power supply must be incorporated in the fixed wiring in accordance with the wiring rules 4 3 Electric wiring diagram a For power supply 230V 50Hz Distribution Box Power Sup...

Page 10: ...ark when it s locked 5 2 Operation Instruction a Screen Lock 1 Press for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation b Power On Press for 3 seconds to unl...

Page 11: ...ss to exit status check mode SYMBOL CONTENT UNIT C0 Inlet water temp C C1 Outlet water temp C C2 Ambient temp C C3 Exhaust temp C C4 Outer coil pipe temp C C5 Gas return temp C C6 Inner coil pipe temp...

Page 12: ...to occur to the Davey heat pump a Turn off the circuit breaker or isolation switch b Drain the Davey heat pump Loosen all water connections c Rinse the interior of the heat exchanger cylinder with a...

Page 13: ...avoided The area around the workspace should be sectioned off Ensure that all conditions within the area have been made safe by control of flammable material 3 Always check the work area with an appr...

Page 14: ...chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed or extinguished If a leakage of refrigerant is found which requires b...

Page 15: ...outlet water Insufficient water flow protection 4 Eb Ambient temperature too high or too low protection 5 Ed Anti freezing reminder No Display Failure Code Description 1 E1 High pressure protection 2...

Page 16: ...mperature difference then either restart the heat pump or go back into standby The default setting is P2 To change these parameters please contact your nearest Davey dealer verter heat pump solution I...

Page 17: ...V 50Hz Customer prepare Power Supply 230V 50Hz Earthing Water pump 230V voltage 500W capacity Breaker fuse Customer prepare Breaker fuse Customer prepare Contactor Powercord 17 Customer remote control...

Page 18: ...18...

Page 19: ...nt Registration Register by e mail or third party application Android iOS a E mail registration Android please download from iPhone please download from 1 APP Download 2 Account registration 1 Registe...

Page 20: ...20 Please set family name and choose location of device Create Family b Register through third party application...

Page 21: ...21 APP Pairing a With Bluetooth 1 Please confirm that you re connected to Wi Fi and your Bluetooth is on 2 Click Add Device and then follow the instructions to pair device...

Page 22: ...d release After hearing Beep enter Wi Fi password in app During connection will flash Once the app connects to Wi Fi successfully will display b With Wi Fi 1 Please make sure you are connected to Wi F...

Page 23: ...r On Off Setting temperature Select Boost Silence Mode 2 For heat pump with Heating Cooling function Compressor speed Query C F switch Setting temperature Select Boost Silence Mode Compressor speed In...

Page 24: ...ather forecast is just for reference 2 App is subject to updates without notice After pairing if your family members also want to control the device please let your family members register InverGo fir...

Page 25: ...tor DHP3503 1 14 403771 Sensors full set 1 16 16294 R32 Compressor DHP130 1 16 16296 R32 Compressor DHP170 210 1 16 16304 R32 Compressor DHP280 1 16 16305 R32 Compressor DHP3503 1 16 16292 R32 Compres...

Page 26: ...26 NOTES...

Page 27: ...27...

Page 28: ...their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions...

Reviews: