Once the salt level in the pool is correct the unit may be switched on. Set
Sanitiser Output
to Max (100%).
The
STAND - BY
indicator will be On and no
Cell Output
will be seen for approx 30 seconds, this allows the
pump and filter to prime and the Cell Housing to fill with water. After this start - up delay, the display should
show 100 (ESR Models (+/-2), unless in
Winter Mode
where it will display 85 (ESR Models (+/-2). At this
point both
Operation LED’s
should be Green; if not there may be a problem. (Refer table).
DISPLAY / INDICATOR
LED 1
LED 2
REASON / ACTION
STAND – BY
ON
Green
Green
1. Start-up delay functioning.
2.
Sanitiser Output
set below max.
Cell is turned off. (Refer
Sanitiser Output
page 7)
FLOW
STAND – BY
ON
Green
Green
1. Gas detected. Check pump/pipes for damage
2. Gas sensor not connected to cell.
FLUCTUATING
AROUND 100
Green
Green
System operating normally.
Green
Red
1. Salt level too low. Add salt at a rate of 25kg
per 25,000L.
2. Cell is calcified. Clean cell.
3. Water temperature low. Switch to
Winter
Mode.
Red
Red
1. Salt level below minimum. Add Salt.
2. Cell is calcified. Clean cell.
3. Water temperature very cold. Switch to
Winter Mode
. Continued operation may
cause damage to system – Consult dealer for
problem rectification.
PLEASE NOTE:
When Winter Mode switch is On Unit will operate similar to above except Display will
fluctuate around 85. (Refer Winter Mode page 8).
AM
6
CONTROL PANEL LAYOUT
OPTIONAL POOL LIGHT
SWITCH
SELECTOR SWITCH
TIME CLOCK
SANITISER OUTPUT DIAL
WINTER MODE SWITCH
OPERATION LED’S