Davey ChloroMatic MC16C Installation & Operating Instructions Manual Download Page 20

Davey

®

 Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within warranty 
periods beginning from the date of original purchase due to faulty materials or manufacture, Davey will at our 
option repair or replace it for you free of charge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that you contact 
the Davey Dealer from which you purchased the Davey product. Alternatively you can phone our Customer 
Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the 
address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty 
or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.

Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product consumables (i.e. 
mechanical seals, bearings or capacitors), loss or damage resulting from misuse or negligent handling, improper 
use for which the product was not designed or advertised, failure to properly follow the provided installation and 
operating instructions, failure to carry out maintenance, corrosive or abrasive water or other liquid, lightning or 
high voltage spikes, or unauthorized persons attempting repairs.  Where applicable, your Davey product must only 
be connected to the voltage shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. Please retain your 
receipt as proof of purchase; you 

MUST

 provide evidence of the date of original purchase when claiming under 

the Davey Guarantee. 

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury 
of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not apply to any 
liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under the 
Australian or New Zealand legislation and does not affect any rights or remedies that may be available to you 
under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any other 
reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods 
fail to be of acceptable quality and the failure does not amount to a major failure.

Should your Davey product require repair or service after the guarantee period; contact your nearest Davey Dealer 
or phone the Davey Customer Service Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

*  Installation and operating instructions are included with the product when purchased new. 

They may also be found on our website.

P/N MMAN008-5 supersedes P/N MMAN008-4

AUSTRALIA
Davey Support Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 367 866

Fax: 

1300 369 119

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND
Davey Support Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

     0800 654 333

Fax:         09 527 7654

Website: daveynz.co.nz

® Davey & ChloroMatic are registered trade marks of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2012.

Davey Guarantee Period

Power Supply - Two Years                         pH Pump Module - One Year

 

 

Electrolytic Cell - Three Years                      Sensor Probe - Three Years 

Summary of Contents for ChloroMatic MC16C

Page 1: ...com au Salt Water Pool System Models MCS16C MCS16CTP MC16C MCS24C MCS24CTP MC20C MCS36C MCS36CP MC30C MCS40C MCS50C Installation Operating Instructions ChloroMatic Please pass these instructions on to...

Page 2: ...with earth bolt 50mm 5 Mounting Kit and Spare Fuse 6 2 x 80 50mm reducing sockets 7 2 x 80mm Nut 8 2 x 80mm Socket Packing List 2 Important Notice 3 Installation Instructions 3 Pre Start Up Procedure...

Page 3: ...l is recommended The Cell is the clear plastic housing containing the removable cell head During the chlorination process a white powdery Calcium scale may naturally build up on the titanium plates in...

Page 4: ...ave been provided for fast and simple installation Simply cut out Template at bottom of page 19 for location of drill entry points Use a 7mm masonry drill bit when fitting Power Supply to a brick or c...

Page 5: ...f pool and allow vacuum to continue for a further 2 or 3 hours Salt should now be completely mixed Never add salt directly into skimmer box CHLORINE For a new pool installation that has not been chlor...

Page 6: ...d off Refer Sanitiser Output page 7 FLOW STAND BY ON Green Green 1 Gas detected Check pump pipes for damage 2 Gas sensor not connected to cell FLUCTUATING AROUND 100 Green Green System operating norma...

Page 7: ...ck its operation simply turn the Sanitiser Output Control to MAX and the Cell will turn ON Once checked adjust the Sanitiser Output Control back to the desired position and after a few minutes the Cel...

Page 8: ...designed to operate at swimming season water temperatures When the pool begins to cool in the off season the temperature drop causes the Cell to behave differently it will draw less electrical curren...

Page 9: ...ime sequence Select the Set Timer 2 ON position on the selector switch A number 4 will appear at the left of the screen This time is factory pre set to 5pm Proceed as per a in the Set Clock instructio...

Page 10: ...the Terminal Block provided Fasten screws Multi voltage connections Refer to table and diagram below for wiring instructions Please Note Only one light can be connected to each light transformer If mo...

Page 11: ...s with hard water reverse polarity systems may require occasional manual cleaning Life of ChloroMatic electrolytic cells vary substantially from one installation to another due to variations in operat...

Page 12: ...spot staining cloudy water etc An incorrect pH level can damage the pool Correct pH levels are as follows Fibreglass 7 2 to 7 4 Concrete tiled 7 4 to 7 6 If you allow the pH level to rise to 8 0 or a...

Page 13: ...N SWIMMING IN THE POOL In extremely hot weather or during periods of heavy bathing loads the running time may need to be extended to 10 14 hours per day In some cases you may find your chlorine level...

Page 14: ...Cell ppm An abbreviation for Parts Per Million the accepted measurement of chemical concentration in swimming pool water I ppm l mg L The appropriate chlorinator size for your pool is dependent on the...

Page 15: ...easured pH SET This will allow adjustment of the controller set point using adjustment tool Turn clockwise to increase the set point Note that acid pump is off when adjusting set point OFF Disables th...

Page 16: ...tance horizontally between Pump Module and Chemical Drum is 1 0 metres 8 Using PVC cement fit Probe Injector Housing to suction or return line before the cell and ensure probe is horizontal to the gro...

Page 17: ...warnings on the acid container Dip the end of the sensor in the solution and move it around for about 20 seconds Rinse the sensor and return it to the manifold The pH Control should be turned off for...

Page 18: ...18 Notes Service History...

Page 19: ...19...

Page 20: ...date of original purchase when claiming under the Davey Guarantee Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoev...

Reviews: