Congratulations on your purchase of a high quality, Davey Aquashield Centurion 
Ultra Violet water treatment system. All components have been designed and 
manufactured to give trouble free, reliable operation.

Model Selection

Davey Aquashield Centurion units are selected according to the maximum water or 
peak flow requirement. As it is not possible to overdose on UV treatment, the unit can 
be oversized for the flow.

The system incorporates pre-filtration to ensure that particulate matter does not 
shield micro-organisms from the UV light. In this system water flows through a 20um 
filter, followed by a 1um filter for removal of sediments and cysts. 

Aquashield Centurion 50W will effectively treat a water flowing at a maximum rate of 
50 litres of water per minute. 

Aquashield Centurion 70W will effectively treat a water flowing at a maximum rate of 
70 litres of water per minute. 

Your new Aquashield Centurion system incorporates a Steriflo, which includes a lamp 
failure system that enables you to be warned of a lamp failure by:-
1. A lamp failure LED.
2. An audible alarm.

In addition when the alarm “beeps” on and off, the lamp is due to be changed so that 
effective treatment is maintained.

Flashing of the red LED indicates that the lamp countdown timer is operating.

Recommendations for maintaining good health

UV sterilising systems are designed to deactivate bacteria by rearranging the 
bacterial DNA and removing the ability of the bacteria to reproduce.

UV treatment is most effective on clear, particle free water. Therefore we include 
20um and 1um pre-filtration prior to the UV chamber. The filters should be checked, 
cleaned and replaced regularly.

As the bacteria in the chamber require sufficient exposure (contact time) with the 
lamp, water flow through the unit should not exceed the maximum flow specified.  
If this is a risk, a flow limiting valve could be added to the system. Please consult 
your plumber.

The UV system is only effective when the lamp has power. In the case of a power 
failure, water should not be used through the system. 

Over time the UV lamp output will be reduced. We recommend replacing the UV 
lamp every 12 months so that your water is treated by high intensity UV.

The internal quartz sleeve needs to be cleaned regularly so that grime on the sleeve 
does not block the UV lamp. This should be done at least 4 times per year and more 
often if your water is prone to scaling.

Summary of Contents for aquashield centurion ASC50

Page 1: ...ning will expose persons to the possibility of personal injury and may result in damage to the UV system or other property This unit is designed to treat water at ambient temperatures 5 C to 45 C Cont...

Page 2: ...Power Surge Protection 4 Power Connection 4 Mounting Plumbing and Start Up 5 LED Indicators 6 Alarms 6 Maintenance 7 Cleaning the quartz sleeve 7 Changing the Filter Cartridge 8 Replacing the UV lamp...

Page 3: ...alarm beeps on and off the lamp is due to be changed so that effective treatment is maintained Flashing of the red LED indicates that the lamp countdown timer is operating Recommendations for maintai...

Page 4: ...from leaking pipe joints or seals Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines and cause serious damage to your electrical equipment The Steriflo...

Page 5: ...lamp The lamp is shipped in a tube in the top of the box Carefully unwrap the lamp and slide it into the pre fitted quartz sleeve through the top of the endcap Connect the lamp connection plugs and p...

Page 6: ...ashing of the red LED indicates normal operation and the lamp countdown timer is operating Should the unit alarm power to the pump will be interrupted ensuring safe water is always supplied Manual ove...

Page 7: ...endcap from the sleeve Lift the quartz sleeve out of the chamber by pulling it straight up Try to handle the quartz sleeve by holding it by the top 2cm Try not to handle the quartz sleeve as fingerpr...

Page 8: ...eaks 5 Screw the housing onto the lid and hand tighten Open the tap downstream of the filter and then open the inlet valve The cartridge spanner supplied with the unit may help if the housing is tight...

Page 9: ...ld for approx 10 seconds The unit should beep to indicate the lamp life timer has been reset The timer will then count down for 12 months and beep alarm when the lamp needs to be replaced Securely wra...

Page 10: ...xposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attent...

Page 11: ...11...

Page 12: ...ors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating inst...

Reviews: