Maintenance

Cleaning the quartz sleeve – 3 monthly

 

(or more often if used with hard water).
If dirt is allowed to build up on the quartz sleeve it will impair the UV output. The 
quartz sleeve should be removed after one month and inspected for deposits.
–  Turn off water supply to the inlet of the Aquashield Centurion system.
–  Disconnect power by unplugging the cordset from the power outlet.
–  Depressurise the system and drain the UV chamber by removing the drain plug. 

Remember to put the plug back on when the chamber is empty. 

–  Unscrew the earth connection.
–  Unscrew the 2 small screws holding the endcap on.
–  This will expose the wiring for the lamp. Disconnect the lamp and remove it 

straight up. Only handle the lamp by the ceramic-coated ends. Place it on a clean 
surface where it is safe.

–  Unscrew the endcap and lift it slightly to reveal the quartz sleeve. The endcap may 

be held on to the sleeve by the o-ring. Gently remove the endcap from the sleeve.

–  Lift the quartz sleeve out of the chamber by pulling it straight up. Try to handle the 

quartz sleeve by holding it by the top 2cm. Try not to handle the quartz sleeve as 
fingerprints can lead to dirt or grease shadows and a loss of efficiency.

–  Use a soft cloth to wipe the quartz sleeve with a solution of CLR (Calcium Lime 

and Rust remover) clean. 

–  Wipe the quartz sleeve with a damp cloth to remove CLR residue. 
–  Reinsert the sleeve to the chamber and refit the o-ring to the top of it. Place the 

pressure ring inside the endcap and hold with your index finger through the central 
hole. Screw the endcap in to place so that it is finger tight. Do not overtighten as it 
can damage the quartz sleeve.

–  Reinsert the lamp and reconnect the wiring. Push the cords into the top of the 

quartz sleeve so that the 2 small screws can be inserted.

–  Connect the earth wire.
–  Refit the drain plug.
–  Plug in the power and turn on. Allow the lamp to run for 2 minutes, turn the water on.
–  If alarm sounds when the power is switched on, turn power off for five minutes to 

allow for internal reset of the power supply.

–  Check for leaks.

Summary of Contents for aquashield centurion ASC50

Page 1: ...ning will expose persons to the possibility of personal injury and may result in damage to the UV system or other property This unit is designed to treat water at ambient temperatures 5 C to 45 C Cont...

Page 2: ...Power Surge Protection 4 Power Connection 4 Mounting Plumbing and Start Up 5 LED Indicators 6 Alarms 6 Maintenance 7 Cleaning the quartz sleeve 7 Changing the Filter Cartridge 8 Replacing the UV lamp...

Page 3: ...alarm beeps on and off the lamp is due to be changed so that effective treatment is maintained Flashing of the red LED indicates that the lamp countdown timer is operating Recommendations for maintai...

Page 4: ...from leaking pipe joints or seals Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines and cause serious damage to your electrical equipment The Steriflo...

Page 5: ...lamp The lamp is shipped in a tube in the top of the box Carefully unwrap the lamp and slide it into the pre fitted quartz sleeve through the top of the endcap Connect the lamp connection plugs and p...

Page 6: ...ashing of the red LED indicates normal operation and the lamp countdown timer is operating Should the unit alarm power to the pump will be interrupted ensuring safe water is always supplied Manual ove...

Page 7: ...endcap from the sleeve Lift the quartz sleeve out of the chamber by pulling it straight up Try to handle the quartz sleeve by holding it by the top 2cm Try not to handle the quartz sleeve as fingerpr...

Page 8: ...eaks 5 Screw the housing onto the lid and hand tighten Open the tap downstream of the filter and then open the inlet valve The cartridge spanner supplied with the unit may help if the housing is tight...

Page 9: ...ld for approx 10 seconds The unit should beep to indicate the lamp life timer has been reset The timer will then count down for 12 months and beep alarm when the lamp needs to be replaced Securely wra...

Page 10: ...xposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attent...

Page 11: ...11...

Page 12: ...ors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating inst...

Reviews: