Installation

Preparing your system

Before installing your new Aquashield Centurion, please read all instructions 
carefully as failures caused by incorrect installation or operation are not 
covered by the guarantee. Your Ultra Violet water treatment system is designed 
to handle clean water. The system should not be used for any other purpose 
without specific referral to Davey. The use of the system with flammable, 
corrosive and other materials of a hazardous nature is specifically excluded.

On removing your Aquashield Centurion system from its carton you should check all 
components to ensure all are present and have not been damaged in transportation. 

Choosing a Site

To protect your Davey Aquashield Centurion from the weather, make sure the site is 
water proof, frost free and has adequate ventilation. Choose a site with a structurally 
appropriate mounting position on the wall. Allow a 

chamber length space above the 

unit

 for removal of the lamp and sleeve from the Steriflo during servicing and 

100mm 

below the cartridges

 for maintenance. 

The unit can be mounted with water flow from left to right, or right to left as 
the plumbing requires. The Steriflo control box may need to be moved. Allow 
for drainage, to avoid damage to flooring etc. that over time may occur during 
maintenance or from leaking pipe joints or seals.

Electrical Power Surge Protection

An electrical power surge or spike can travel on the supply lines and cause serious 
damage to your electrical equipment. The Steriflo control box has a fuse to protect 
the circuit. The fuse is not a lightning arrestor and may not protect the Steriflo if 
lightning or a very powerful surge hits the unit.
If the installation is subject to electrical power surges or lightning we strongly 
recommend the use of suitable additional surge protection devices on all electrical 
equipment. 

We recommend the use of an RCD or earth leakage circuit breaker

 

on the power supply to your unit.

Power Connection

Connect lead to power supply designated on control box label. Do not use long 
extension leads as they may cause substantial voltage drop and/or poor lamp 
performance. The stainless steel chamber is connected to earth as supplied and this 
connection must always be used during operation.
The control box has a female power socket that can be used to power a pump. In the 
event of a lamp failure, power to the pump will be shut off to ensure untreated water 
is not delivered.

Ensure flow rate of the pump does not exceed rated flow of the UV 
system or maximum rated current draw of 5.7A.

CAUTION: The supply cord is necessary for lamp changing. The three pin 
supply plug must remain accessible after installation. If installed to fixed 
wiring without the plug a two pole switch must be fitted and its ON and OFF 
positions shall be marked.

Summary of Contents for aquashield centurion ASC50

Page 1: ...ning will expose persons to the possibility of personal injury and may result in damage to the UV system or other property This unit is designed to treat water at ambient temperatures 5 C to 45 C Cont...

Page 2: ...Power Surge Protection 4 Power Connection 4 Mounting Plumbing and Start Up 5 LED Indicators 6 Alarms 6 Maintenance 7 Cleaning the quartz sleeve 7 Changing the Filter Cartridge 8 Replacing the UV lamp...

Page 3: ...alarm beeps on and off the lamp is due to be changed so that effective treatment is maintained Flashing of the red LED indicates that the lamp countdown timer is operating Recommendations for maintai...

Page 4: ...from leaking pipe joints or seals Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines and cause serious damage to your electrical equipment The Steriflo...

Page 5: ...lamp The lamp is shipped in a tube in the top of the box Carefully unwrap the lamp and slide it into the pre fitted quartz sleeve through the top of the endcap Connect the lamp connection plugs and p...

Page 6: ...ashing of the red LED indicates normal operation and the lamp countdown timer is operating Should the unit alarm power to the pump will be interrupted ensuring safe water is always supplied Manual ove...

Page 7: ...endcap from the sleeve Lift the quartz sleeve out of the chamber by pulling it straight up Try to handle the quartz sleeve by holding it by the top 2cm Try not to handle the quartz sleeve as fingerpr...

Page 8: ...eaks 5 Screw the housing onto the lid and hand tighten Open the tap downstream of the filter and then open the inlet valve The cartridge spanner supplied with the unit may help if the housing is tight...

Page 9: ...ld for approx 10 seconds The unit should beep to indicate the lamp life timer has been reset The timer will then count down for 12 months and beep alarm when the lamp needs to be replaced Securely wra...

Page 10: ...xposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attent...

Page 11: ...11...

Page 12: ...ors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating inst...

Reviews: