PSM-500/500L/500LT SCPC Satellite Modem
Operation
PSM-500/500L/500LT - Rev. 0.91
Page 3-13
Unit Parameter Detail
Representation
Type
Entry
Description
Redundcy Sw Hold
.5 Sec
Numeric
0.0 to 600.0 seconds in 0.1
second increments.
Sets the minimum time that
a redundancy alarm must
last before switching occurs.
Redundcy Backup
Idle
Selection
Backup Status or Press “0”
or “Edit” then “Enter” to
transfer current
configuration to backup.
View status of or configure
backup. Only available when
on-line.
Config Modem
Mod & Demod
Selection
0 = Disable,
1 = Demod Only,
2 = Mod Only,
3 = Mod & Demod
Used to disable the Mod or
Demod and also the lamps
and indications when not
used.
Config Recall
Factory, 1 to 8
Selection/
Numeric
0 to 8, 0 = Factory
Location to recover current
configuration from.
Config Store
Factory, 1 to 8
Selection/
Numeric
1 to 8, Factory configuration
not alterable
Location to store current
configuration to.
Config Restore 1
After 1 Sec
Selection/
Numeric
Disabled (0), 1 to 14,400
seconds
Time after loss of rcv carrier
to restore this configuration.
...Restore 2-7
…
Config Restore 8
Disabled
Selection/
Numeric
Disabled (0), 1 to 14,400
seconds
Time after loss of rcv carrier
to restore this configuration.
Config Power-Up
Last
Selection/
Numeric
Last (0), Recall 1 to 8
Behavior on power-up.
Either the last settings or try
to lock using one of the
stored configurations.
Keybrd Mode
Full Access
Selection
0 = Disable,
1 = Read Only,
2 = Full Access
Keyboard access control.
Keybrd Entry
Quick
Selection
0 = Quick,
1 = Edit Only
2 = Confirm
Keyboard Entry method.
Quick is the normal default
mode.
Keybrd LCD Active
Backlight Full
Selection
0 = off, 1 = 1/3, 2 = 2/3, 3 =
Full
Active level of LCD backlight
Keybrd LCD Idle
Backlight 1/3
Selection
0 = off, 1 = 1/3, 2 = 2/3, 3 =
Full
Idle level of LCD backlight
Keybrd LCD Cntst
10
Numeric
0 to 20
LCD Contrast setting
Keybrd Activity
Beep
Selection
0 = None,
1 = Beep,
2 = Blink,
3 = Beep & Blink
Audible “click” and/or “Local”
LED Blink on front panel key
press.
Remote Mode
Full Access
Selection
0 = Disable,
1 = Read Only,
2 = Full Access.
Remote control access
mode allowed