14
Operation
SPL2(TS) and SPL3(TS) user manual
EN
Error messages
There are a few error situations in which the limiter will switch off its output, while one of the LED's at
the front will blink to indicate that there is something wrong.
DETECT-LED (8) blinking: limiter is initialising after switching the power on. This
situation will not last langer than a 2 seconds.
DETECT- & WARNING-LED (8) (11) blinking: limiter is initialising after switching
the power on. In this case, the measuring microphone is switched on.
WARNING- & SANCTION-LED (11)(12) blinking: the supplied microphone is not
connected correctly. Check the connection.
BYPASS-LED (7) blinking: the limiter is in BYPASS-mode, and will simply pass
all audio on the input directly to the output.