TECHNICAL SPECIFICATIONS

 

 

Keyboard and Buttons 

Two Scan buttons 
Reset device button 

Contactless Card Reader 

(optional) 

Supports: 
ISO/IEC 14443 Type-A/MIFARE 
- MIFARE MINI 
- MIFARE CLASSIC-1K, MIFARE CLASSIC-4K 
- MIFARE ULTRALIGHT, ULTRALIGHT-C 
- MIFARE PLUS 2K/4K 
- MIFARE DESFire  
- and other  
ISO/IEC 14443 Type-B 
- supports most of the cards 
ISO/IEC 15693 
- supports most of the cards 
JIS X 6319-4 
- compatible with FeliCa 
ISO/IEC 18000-3 mode 3 
- NFC 

2D Barcode Reader 

2D Opticon MDI-4000* CMOS Imager 640 x 480 pixels (optional) 
2D Motorola SE4750/PL3307 CMOS Imager 1280 x 960 pixels, Laser Aim (optional) 

Supported 1D and 2D 

Symbology* 

BARCODE 1D: JAN/UPC/EAN incl. add on, Codabar/NW-7, Code 11, 
Code 39, Code 93, Code 128, GS1-128 (EAN-128), GS1 DataBar (RSS), 
IATA, Industrial 2of5, Interleaved 2of5, ISBN-ISSN-ISMN, Matrix 2of5, MSI/ 
Plessey, S-Code, Telepen, Tri-Optic, UK/ Plessey POSTAL CODE: Chinese 
Post, Intelligent Mail Barcode, Korean Postal Authority code, POSTNET 
2D CODE: Aztec Code, Aztec Runes, Chinese Sensible code, Codablock F, 
Composite codes, Data Matrix (ECC200), Passport MRZ (OCR-B), Maxi Code 
(mode 2~5), MicroPDF417, Micro QR Code, PDF417, QR code 

Connectivity 

Apple 9 pin connector  
Pass-through sync through USB type-C 
Pass-through sync through via GT1 or GT5 
Bluetooth 3.0 Class 2 (option)  
- SPP - Serial Port Profile 
SAM holder 

Device Compatibility 

Apple iPhone 7 and iPhone 8 

Audio Features 

Electro-Magnetic Buzzer

 

Power Supply 

DC 5V through USB type-C   
DC 5V through Datecs charging station   

Battery 

Rechargeable Li-Ion Battery 3.6V / 2400mAh  
Precise battery management by Fuel Gauge microcontroller for remaining battery 
capacity

 

Certificates 

IP65 

Dimension W x H x D, mm 

75.1 x 25.6 x 157.4 

Weight, g 

 

Operational temperature range 

-

10 °C to +40 °C / 5 to 90% RH

 

Storage temperature range 

-

20 °C to +50 °C / 5 to 90% RH

 

Compatible Accessories 

Single charger (GT1)  
5 stations charger (GT5) 
Dual Charger  

* Specification can be change without any notice.  
 

 

Summary of Contents for LineaPro 7 Industrial

Page 1: ...1 DATECS LineaPro 7 Industrial User Manual ...

Page 2: ...E INFORMATION IN THIS DOCUMENT CANNOT BE REPRODUCED IN ANY MECHANICAL ELECTRICAL OR ELECTRONIC WAY AND UNDER ANY CIRCUMSTANCES WITHOUT THE WRITTEN CONSENT FROM DATECS LTD Address 4 Datecs Street Sofia 1592 Bulgaria Phone 359 2 816 55 50 Fax 359 2 816 55 65 E mail export datecs bg ...

Page 3: ...1 DATECS LINEAPRO 7 INDUSTRIAL USER MANUAL UM 07 01 12 v1 0 0 3 REVISION HISTORY Version Data Change description 1 0 0 14 12 2017 First Release 2 0 0 10 03 2020 Added Section Regulatory ...

Page 4: ...TARTED 10 ATTACHING APPLE DEVICE TO LINEAPRO 7 INDUSTRIAL 11 REPLACING BATTERY OF LINEAPRO 7 INDUSTRIAL 13 OPERATION MODES 15 SCANNING BARCODES 15 CONTACTLESS CARDS READING 16 TRANSFERRING DATA BETWEEN APPLE DEVICE AND PC OR MAC 17 TURN OFF DEVICE FUNCTION 17 CHARGING APPLE DEVICE 17 UPDATING FIRMWARE 17 CARE MAINTENANCE AND WARRANTY 18 ...

Page 5: ...y approved by Datecs Ltd could void the user s authority to operate the device RF Exposure Information and Statement This transmitter must not be in co location or operating in conjunction with any other antenna or transmitter This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This device should be installed and operated with a minimum distance of ...

Page 6: ...Telepen Tri Optic UK Plessey POSTAL CODE Chinese Post Intelligent Mail Barcode Korean Postal Authority code POSTNET 2D CODE Aztec Code Aztec Runes Chinese Sensible code Codablock F Composite codes Data Matrix ECC200 Passport MRZ OCR B Maxi Code mode 2 5 MicroPDF417 Micro QR Code PDF417 QR code Connectivity Apple 9 pin connector Pass through sync through USB type C Pass through sync through via GT1...

Page 7: ...r is 5V 2 1A Waste Electrical Electronic Equipment The symbol means that according to local laws and regulations your product shall be disposed of separately from household waste at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustain...

Page 8: ...1 DATECS LINEAPRO 7 INDUSTRIAL USER MANUAL UM 07 01 12 v1 0 0 8 GENERAL VIEW ...

Page 9: ...v1 0 0 9 1 Barcode engine 7 Opening for 2 Back Cover 8 Linea battery cover lock unlock lever 3 On Off button of Apple device 9 Battery cover 4 Left and Right scan buttons 10 External features connector 5 USB type C connector 6 Volume buttons of Apple device ...

Page 10: ...res connector Before first use battery must be fully charged If the device is fully discharged charging time to fully charged would be approx 4 hours and 30min Depends of the settings LineaPro 7 Industrial can pass through input power supply from USB connector or External features connector to Apple device Charging current to Apple device can be selected Charging form USB adapter ...

Page 11: ...APRO 7 INDUSTRIAL USER MANUAL UM 07 01 12 v1 0 0 11 ATTACHING APPLE DEVICE TO LINEAPRO 7 INDUSTRIAL First is need to be removed back cover Then must be slide down iPhone to Linea Pro 7 Industrial lightning connector ...

Page 12: ...1 DATECS LINEAPRO 7 INDUSTRIAL USER MANUAL UM 07 01 12 v1 0 0 12 Slide until completely fit of the iPhone to LineaPro 7 Industrial Place back cover to LineaPro 7 ...

Page 13: ...USER MANUAL UM 07 01 12 v1 0 0 13 REPLACING BATTERY OF LINEAPRO 7 INDUSTRIAL The rechargeable battery of Linea can be replaced Put the lever 1 to unlock position then pull up the battery cover 2 Remove old battery with pulling up 1 2 ...

Page 14: ... side with contacting pads of the battery then press it down Direction of battery cover closing Place the clips to correct position When the battery cover is completely closed slide the lever to lock position Replace battery only with new original battery with part number PL 15 110 ...

Page 15: ...D barcodes To scan barcode first activate the scanner by pressing and holding the scan button Then position the scanning engine to the center of the barcode by aiming and the illumination box is over the outer edges of the barcode as shown on the picture below Slowly pull back or forward the unit while increasing or decrease the distance between the barcode and the scanning head until the barcode ...

Page 16: ... 07 01 12 v1 0 0 16 Contactless cards reading The LineaPro 7 Industrial has a contactless card reader Contactless card reader is located on the bottom side Contactless card tag or etc must be placed over the RF ID logo showed on the picture below ...

Page 17: ...er source USB adapter is attached to USB connector or LineaPro 7 Industrial is placed on Datecs charging station Charging current to Apple device can be selected from application 500mA Default 1000mA LineaPro 7 Industrial can charge Apple device from his own battery Only is need to be activated function Automated Charge to be start charging battery level of LineaPro 7 Industrial must be above 20 U...

Page 18: ...o not drop or knock LineaPro 7 Industrial Do not open the LineaPro 7 Industrial Only qualified personnel can open the device and make repair If the LineaPro 7 Industrial is not working please contact with your dealer Allowing unqualified personnel to service your LineaPro 7 Industrial may result in damage to your LineaPro 7 Industrial and will void your warranty ...

Reviews: