background image

 

 

 
 
 
 
 

DT1010 xx xx 

 
 

Temperature / Resistance / Potentiometer Transmitter 

 
 
 
 
 

Operating Instructions 

 

 

Summary of Contents for DT1010 Series

Page 1: ...DT1010 xx xx Temperature Resistance Potentiometer Transmitter Operating Instructions...

Page 2: ...iguration 6 3 2 Type designation 6 3 3 Principle of operation 7 3 4 Adjustment 7 3 5 Indicators USB connector 8 3 6 Storage and transport 9 4 Mounting 10 4 1 General instructions 10 4 2 Main dimension...

Page 3: ...ing 24 7 9 Two wire zeroing 25 7 10 Sensor correction values 26 7 11 Potentiometer calibrating 28 7 12 Potentiometer scaling 30 7 13 New password setting 31 7 14 Resetting default settings 32 7 15 Ana...

Page 4: ...f this manual should be made available to these personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning dan...

Page 5: ...tion specific hazards or damage to system components through incorrect mounting or adjustment 2 4 General safety instructions The DT1010 xx xx is a high tech instrument requiring the strict observance...

Page 6: ...6 20180403 V1 3 Product description 3 1 Delivery configuration Delivered items The scope of delivery encompasses DT1010 xx xx documentation this operating instructions certification warranty 3 2 Type...

Page 7: ...x xx via USB port The measuring current flows through the sensor resistance potentiometer connected to the input The voltage drop on the measuring sensor is compared with the voltage drop on the inter...

Page 8: ...tinuous light indicates that the instrument is in measuring mode a short flash indicates that a successful communication has granted with the configuration software 2 st red indicator has two function...

Page 9: ...nder the title Environmental conditions The packaging of DT1010 xx xx consist of environment friendly recyclable cardboard is used to protect the instrument against the impacts of normal stresses occu...

Page 10: ...accordance with chapter 10 1 Technical specification as described under the title Operating conditions Mounting position The instruments are designed in a housing for mounting on TS 35 rail The instr...

Page 11: ...unting doesn t need any tool 1 Tilt the instrument according to the figure put the instrument s mounting hole onto the upper edge of the rail figure step 1 2 Push the instrument s bottom onto the bott...

Page 12: ...ce of supply voltage Use only a screwdriver with appropriate head Take note the suitability of the connecting cable wire cross section insulation etc The wire cross section should be 0 25 1 5 mm2 You...

Page 13: ...potentiometer to the input see also Application example Checking the Connections 1 Loosen terminal screws 2 Insert the wire ends into the open terminals according to the wiring plan 3 Screw the termi...

Page 14: ...erminals according to the wiring plan 3 Screw the terminal in 4 Check the hold of the wires in terminals by pulling on them firmly Check if the cables are connected properly have you connected all the...

Page 15: ...lt settings Sensor connecting 4 wire Measuring mode temperature measurement Current output 4 20 mA Current output error value 3 2 mA Averaging 16 measurement Output refresh time 0 5 sec Sensor charact...

Page 16: ...links potentiometer mode is selected but the potentiometer is not calibrated see Chapter 7 4 blinks measuring value out of range 5 blinks analog output scaling error the instrument is unable to conver...

Page 17: ...Simple copy it into an optional folder click on the Start button and you can configure the instrument Setting up 1 Connect the instrument with the USB cable to the PC USB port and put it under supply...

Page 18: ...le resistances The 3 wire mode is a compromise it may give a good result when all the 3 wire have same resistance The two wire mode is the cheapest mode use only when there is no other possibility Fac...

Page 19: ...ce of operations Temperature transmitter measured in C with 0 1 C resolution Factory default Potentiometer transmitter measured in percent between 0 100 with 1 resolution Potentiometer transmitter wit...

Page 20: ...ire break can be detected by the signal processing unit it can drive a loop indicator e g DT4200 7 5 Error current voltage setting Function In a case of an error state the output current voltage is fo...

Page 21: ...sing this number the signal stability increases but the signal settling time becomes lower Default factory setting 16 1 Select the appropriate output signal by clicking the button The figure shows the...

Page 22: ...DT1010 xx xx 22 20180403 V1 Settling time after stabilizing the input signal 3 wire mode Averaging number Settling time sec 1 0 25 2 0 5 4 1 0 8 1 8 16 3 5 32 6 8 64 13 6...

Page 23: ...put current voltage refresh time can be set independently from the measuring time There are 6 different refresh times sec 0 1 0 3 0 5 1 0 1 5 2 0 1 Select the appropriate output signal by clicking the...

Page 24: ...eter scale to the output Factory default 4 mA 200 0 C and 20 mA 800 0 C 1 Type in the value of the start point of the range or scale 0 4 mA or 0 2 V 2 Type in the value of the end point of the range o...

Page 25: ...will work only properly at the same ambient temperature Factory default wire resistance 0 Ohm This setting will work only when the two wire mode is selected Sequence of operations 1 Short the connect...

Page 26: ...e correction values and using interpolation method on all other points of the whole characteristics For the best curve fitting it is recommended to choose the correction points at about 20 50 80 of th...

Page 27: ...DT1010 xx xx 20180403 V1 27 The figure shows the factory default settings Sequence of operations 2 Type in the 3 temperature value 3 Type in the bold resistance difference values The setting is ready...

Page 28: ...the instrument to the potentiometer scale If the potentiometer is not calibrated the st indicator signs the error with 3 blinking 1 The figure shows the state before calibrating In the R window you c...

Page 29: ...r wiper to the end position than click on the right button You will see on the right button the resistance value of the potentiometer in the end position Note Any wiper position can be assign to the 0...

Page 30: ...art and end position of the potentiometer The figure shows the factory default settings Sequence of operations 1 Select the number of decimals 2 Type in the start resistance value 0 upper window than...

Page 31: ...into the lower field The figure shows an example when the selected password is 2587 Sequence of operations When the two password is not the same the software announces it and you have to type in twic...

Page 32: ...ng this function makes sense in that case when the settings of the instrument have changed so much that it is easier to start the setting up process from the default factory setting 1 Click on the Fac...

Page 33: ...e the error state See 7 16 Analogue output error state disabling 1 Type in the low and the high output limits In voltage mode the typed value is desired voltage value x2 The figure shows the factory d...

Page 34: ...e is OK the instrument is defective There is no output signal check the device connected to the input When the result of fault finding is that the DT1010 xx xx is defective call the manufacturer servi...

Page 35: ...it possible to open the fixing assembly figure step 2 4 Keeping the screwdriver in this position lift the instrument bottom from the bottom edge of the rail figure step 3 Lift the whole instrument you...

Page 36: ...4000 Number of correction points 3 Output parameters Output signal DC current DC voltage Output ranges 4 20 mA 0 20 mA 2 10 V 0 10 V Overload 21 mA or 10 5 V Scaling Linear with optional start and en...

Page 37: ...70 C Relative humidity 90 max non condensing Place of installation cabinet Mounting position vertical horizontal rail position Electromagnetic compatibility EMC Accordance with the standard EN 61326 1...

Page 38: ...DT1010 xx xx 38 20180403 V1 10 2 Application example...

Page 39: ...DT1010 xx xx 20180403 V1 39...

Page 40: ......

Reviews: