![Datavideo SEB-1200 Instruction Manual Download Page 82](http://html1.mh-extra.com/html/datavideo/seb-1200/seb-1200_instruction-manual_3832583082.webp)
82
Appendix 2: GPI Out
The SE-1200 MU can control external recorder/playback devices via simple contact closure GPI switch.
The GPI interface is a 3.5mm Jack Socket which is situated on the rear panel of the SE-1200 MU.
Contact closure between the Outer and Inner contacts on the jack plug will trigger a user selected event.
Power is supplied by the SE-1200 MU and is less than 5V DC.
This GPI socket can also be used as a socket to trigger record or playback events with other equipment
such as the Datavideo HDR-70 recorder.
SAFETY FIRST
The cabling required needs to be designed specifically to connect the SE-1200 MU to the
chosen record or playback device as they are not all the same. The cabling required can be made by
yourself or a competent technician. Please speak with your Dealer or local Datavideo office to get further
help and advice.
Outputs Menu
This allows the user to perform GPI configuration.
Windows PC Users
MAC Users
After turning
On
the GPI
Enable
, select the GPI
Mode
, which is either set as
Level
or
Pulse
. The GPI signal
Width
can also be configured by setting a value (1~9).
The GPI out can then be assigned to one of the inputs 1~4 under
Source
. When the selected
channel/source is taken to the Program output the GPI signal is triggered. A GPI
Delay
can be set between
0 and 99.
This feature could be used to trigger playback from units such as the Datavideo
NVP-20
or
HRS-30
or
HDR-
60/70
.