Appendix 2 Firmware Update
Datavideo usually releases new firmware containing new features or reported bug
fixes from time to time. Customers can either download the NVS-30 firmware as they
wish or contact their local dealer or reseller for assistance.
This section outlines the firmware upgrade process which should take
approximately
10 minutes to complete
.
The existing NVS-30 settings should persist through the
firmware upgrade process,
which should not be interrupted once started
as this could result in a non-
responsive unit.
Successful firmware upgrade on NVS-30 requires:
The latest firmware file, which can be obtained from your local Datavideo dealer
or office.
A MAC or PC computer with web browser on the same IP network as the NVS-30.
Datavideo Utility Software
(can be downloaded from Datavideo’s official website)
The current NVS-30 IP address and settings (
Network Connection and IP Address
)
1.
Power ON NVS-30 and connect it to an Ethernet network.
2.
Open Datavideo Utility Software on a computer that is on the same network
subnet as the NVS-30 that you want to update.
Note: You cannot update the NVS-30 firmware over a wireless network.
3.
On the
Datavideo Utility Software,
select the network
IP Address
of the NVS-30
device that you want to update, and then click
Update Selected
.
4.
If you have multiple NVS-30 devices on the network, select the IP address for
every device on the Datavideo Utility Software by clicking
Select All
, and all NVS-
30 devices will be updated in sequence.
Note: The NVS-30 device will be turned on and off at different times during the
update process. The update is complete when all LEDs are turned off except the
Power, Stream, Record, and USB port 1 LEDs.
It is not recommended to simultaneously update the same NVS-30 device using
more than one instance of the Datavideo Utility Software.