15
W.BAL White Balance Modes Selection Toggle Switch
This toggle switch allows users to select three White
Balance modes including AWB, AWB Lock and MWB.
The toggle switch controls the position of the LED signal
on the left side. The initial position of the toggle switch is
located at the “Exposure Lock”.
Pull up the toggle switch to the top will set the mode
to AWB (Auto White Balance).
Pull the toggle switch to the middle will set the
mode to AWB Lock.
Pull the toggle switch to the bottom will set the
mode to MWB(Manual White Balance), and the next
page, MWB block will be activated.
Manual White Balance Mode & Parameters Control
Buttons Set
There are several buttons in this set including “MWB
PRO”, “COLOR TEMP. +/-“, “R GAIN +/-“, “B GAIN +/-“ for
users to adjust the Manual White Balance mode and
related parameters.
FOCUS Mode Selection Toggle Switch and Focal Length
Adjusting Knob
FOCUS Mode Selection Toggle Switch
This toggle switch allows users to select three Foucs
modes including A (Auto FOCUS), M (Manual FOCUS) and
LENS (LENS FOCUS).
Pull the toggle switch to the top will set the mode to
A.
Pull the toggle switch to the middle will set the
mode to M. At this time, the focal length adjustment
knob which is located on the right side can be
controlled by users.
Pull down the toggle switch for one time (to the
bottom) will turn off the FOCUS function (FOCUS
OFF).
Focal Length Adjustment Knob
This Focal Length Adjustment Knob can be controlled by
users only when the FOCUS toggle switch is located at M
(Manual Focus Mode).
When the knob is turned clockwise, it will cause long focal
length.
When the knob is turned counter clockwise, it will cause
short focal length.