background image

1.0 - INTRODUCTORY NOTE

WARNING

!

CAUTION

NOTE

Page 3

Homologation number 7854T Cat 1:

TQA426

NOTE: please send a copy to the insurance company if necessary.

UK

CONTENTS

PAGE 3

PAGE 4

PAGE 4

PAGE

PAGE

PAGE

PAGE 5

PAGE 5

PAGE 5

4

5

5

PAGE 5

PAGE 6

PAGE 6

PAGE 6

PAGE 7

PAGE 7

PAGE 7

PAGE 7

PAGE 8

PAGE 8

PAGE 8

PAGE 8

PAGE 8

PAGE 9

PAGE 9

UK

CONTENTS

1.0 - INTRODUCTORY NOTE...........................................................

2.0 - ALARM CONTROL DEVICES...................................................

2.1 - Remote control........................................................................

2.2 - Override key............................................................................

3.0 - ALARM OPERATION................................................................

3.2 - Passive immobilisation............................................................

3.3 - Topcase/Seat open warning signal.........................................

3.4 - Arming delay............................................................................

3.5 - Siren exclusion (mute alarm)...................................................

3.6 - Motion sensor exclusion..........................................................

3.7 - Full arming...............................................................................

3.8 - Alarm events............................................................................

3.9 - Limiting acoustic signals..........................................................

3.10 - Neutral time between alarms.................................................

3.11 - System disarming without alarm memory..............................

3.12 - System disarming with alarm memory...................................

4.0 - PROGRAMMABLE FEATURES................................................

4.1 - Acoustic signals.......................................................................

4.2 - Panic alarm.............................................................................

5.0 - Sleep mode Activation/Deactivation..........................................

6.0 - Use and maintenance...............................................................

7.0 - Replacing remote control batteries...........................................

8.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT........

3.1 - Arming.....................................................................................

Provides useful information.

Non-compliance to this instruction will result in serious damage to the alarm

system and the vehicle itself.

Non-compliance to this instruction may cause serious damage or operational

failures to the alarm system.

Dear

 

Customer,

Thank you for choosing a 

Datatool

 product. This Thatcham approved 

7854T alarm system has been designed and manufactured in Italy 

specifically for two-wheeled vehicles.

Please read the present manual carefully to familiarise yourself fully with the 

alarm system features and operating procedures and do keep it handy for 

future reference.
The following signal words are used throughout this manual to emphasize 

important instructions or special information.

Page 2

Datatool declare that the radio equipment is in compliance with 

Directive 2014/53/EU.

R&TTE DECLARATION OF CONFORMITY

Summary of Contents for EVO PRO

Page 1: ...User Guide Rev 01 07 22 Datatool is a brand of Scorpion Automotive www datatool com 01257 249928 Scorpion House Drumhead Road Chorley PR6 7DE P N 02000147 ...

Page 2: ...nals 4 2 Panic alarm 5 0 Sleep mode Activation Deactivation 6 0 Use and maintenance 7 0 Replacing remote control batteries 8 0 WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT 3 1 Arming Provides useful information Non compliance to this instruction will result in serious damage to the alarm system and the vehicle itself Non compliance to this instruction may cause serious damage or operational failures ...

Page 3: ...losed a BOP will sound after the arming confirmation tones Thealarmwillarmbutanalarmconditionwillbetriggeredafterthearmingdelay 3 4 Arming delay There is a 20 sec activation delay from the time the system is armed During the arming delay the LED is ON steady it will start flashing as soon as the system will be fully armed Engine immobilisation and optional module inputs are immediately enabled 3 5...

Page 4: ...rming the alarm press button 2 To comply with the regulations in force aimed at limiting noise pollution To save power and maximise vehicle battery life If after8 times no one checksthe vehicle itisuseless to have itsound again Battery Disconnection Ignition attempt Motion detection ex lifting towing forcing the steering lock Seat topcase unauthorized access Panic siren button 2 Page 7 3 11 System...

Page 5: ...ng care not to damage the internal circuit Remove the discharged batteries and insert the new ones taking care not to invert the polarity Close the plastic shells and make sure the remote works properly 6 0 USE AND MAINTENANCE Care should be taken to protect the electronic alarm system Do not clean the alarm with water but use a damp cloth to wipe Do not expose the alarm to heat sources Do not use...

Reviews: