SCS1
Series
Instruction
Manual
26
1. Opening a new inspection
The creation of a new inspection can be selected either from the menu or from the toolbar.
Toolbar Menu
Once the “New Inspection” is selected, the system enters automatically in the
Live mode
. The
images acquired by the sensor are visualised in this mode.
An application example is herein provided.
The application consists in the counting of tablets in a blister and integrity control. Figure 10 shows
the image visualised during the
Live mode
phase.
Figure 10
The user can control what the sensor acquires during
Live mode
and so all aspects concerning the
quality of the acquired image have to be optimised.
This is a key operation to guarantee the success of the application.
2. Positioning
Position the target-object inside the field of view.
3. Resolution
Select the resolution of the image to visualise.
Different resolutions are available: VGA (640x480 pixel) and ¼
VGA (320x240 pixel).
A larger working field is obtained by selecting VGA while ¼ VGA
favours inspection speed, reducing the image acquisition time.
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]