Instruction
Manual
SCS1
Series
11
Ethernet Cable
Crossover
Ethernet Cable
The PC and sensor connection can be established
directly
or using a
LAN network
.
3.3.3.
Direct connection
An Ethernet crossover cable (with TX and RX crossed
wires) has to be used in presence of a direct PC and
sensor connection and the sensor and PC IP addresses
must be configured
3.3.4.
LAN network connection
A traditional Ethernet cable has to be used in
presence of a PC and sensor connection using a LAN
network. Assure that the sensor IP address is
compatible with the existing network.
If PC and sensor are connected directly, the user has
more freedom in configuring the IP address. On the
contrary, if the PC is connected to the sensor using a
local LAN network, intrinsic constraints regarding the
existing network configuration have to be respected.
For this reason the sensor’s IP address can be changed using push-buttons and thus guaranteeing
improved system flexibility.
If the PC’s IP address is unknown, the user can find it as follows:
1. open a DOS window (from the
menu and select “Run”, type “cmd” and click on
OK);
2. type
“ipconfig”;
3. press
“Enter”.
The necessary information is then shown:
Figure 7