Modem Certifications 

 
The following countries have certified the internal modem.  In order to comply with local regulations, the countrycode 
must be set to the country of installation.  To set the modem for the desired country use the CLI command 

set modem 

countrycode <countrycode>.  

Use the 

get modem

 command to display the current country setting.   

 

Note:  Use of the wrong countrycode violates local laws and the warranty of this product. 

 
 

Country 

countrycode 

Argentina  

07 

Australia  

09  

Austria  

253 

Belgium  

253 

Canada  

181 

China  

181 

Cyprus  

253 

Czech Republic  

253 

Denmark  

253 

Finland  

253 

France  

253 

Germany  

253 

Greece  

253 

Hong Kong  

153 

Hungary  

253 

Iceland  

253 

Indonesia  

153 

Ireland  

253 

Italy  

253 

Japan  

00 

Korea  

181 

Liechtenstein  

253 

Luxembourg  

253 

Mexico  

181 

Netherlands  

253 

New Zealand  

126 

Norway  

253 

Philippines  

181 

Portugal  

253 

Slovak Republic  

253 

Spain  

253 

Sweden  

253 

Switzerland  

253 

Taiwan  

254 

United Kingdom  

253 

United States  

181 

Summary of Contents for iBootBar iBP-2C10

Page 1: ...MA 20 Amp 8 x NEMA 5 15 IP Control Serial Control Internal Modem iBP 2N20 2 x NEMA 40 Amp 8 x NEMA 5 15 IP Control Serial Control iBP 2N20 M 2 x NEMA 40 Amp 8 x NEMA 5 15 IP Control Serial Control Int...

Page 2: ...4 Installation 5 Configuration 7 Basic Operation 9 Command Line Interface Direct Messaging Protocols Advanced Operations 14 Frequent Outlet Control Multi Outlet Control DTMF Control AutoPing Email Not...

Page 3: ...efeat the safety purpose of the grounding type plug Do not use a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9...

Page 4: ...ty The iBP has many features to make the management of power distribution simple and cost effective 8 Independently controllable outlets Dual power inputs for redundant power feeds Support for dual re...

Page 5: ...the iBP to the standard 19 inch rack Ethernet The iBootBar has a 10 100 Ethernet port The default address is 192 168 0 254 Serial Port The iBootBar has a 9 pin D subminiature connector for RS 232 seri...

Page 6: ...mum current load for all outlets cannot exceed 12 Amps at 115VAC or 10 Amps when used at 240VAC The iBP 2C10 M is for international applications and can be used on 100V to 240VAC The iBP 2C10 provides...

Page 7: ...em 2 Automatically from a DHCP Server 3 ARP Ping To configure the mode to set the IP address access the iBootBar command line interface CLI and use the set ipmode command as indicated below Setting th...

Page 8: ...ted decimal for the iBootBar and the MAC address is the MAC Address of the iBootBar The MAC Address of the iBootBar is located on the rear of the unit Example arp s 63 211 86 165 00 50 c2 05 01 c1 ent...

Page 9: ...ycle The cycle time is the length of the reboot or power on In seconds 0 99 set cycle n get console Display current console configuration set console timeout 30 3600 disable Console can be set to auto...

Page 10: ...address of the iBootBar set ipaddress dotted decimal Set the current IP address ipmode must be set to static to use this command set subnet dotted decimal Set the Subnet Mask set gateway dotted decima...

Page 11: ...e Byte status for each outlets all 8 Bytes of status for each command Verbose Status for controlled outlet only Basic Syntax esc pass esc outlet cmd esc pass outlet cmd CR iPAL Protocol esc pass esc o...

Page 12: ...Outlet ON C Cycle Outlet Cycle can be On Off On or Off On Off depending on starting status T Set Cycle Time Cycle time in seconds Valid range 1 99 Get Status Outlet number optional No outlet number w...

Page 13: ...er on or off to improve product life expectancy for example set outlet 1 initial state on set outlet 4 initial state off Multi Outlet Control Command This command is used to operate all eight outlets...

Page 14: ...e key is used to reboot or power cycle the outlet for the time configured with the CLI command cycle time The new status of the outlet is stated If the key is used the iBootBar will also state begin t...

Page 15: ...low Upon triggering iBootBar will power off the assigned outlet When the ping response returns iBootBar will power the outlet on Cycle Upon triggering iBootBar will cycle the power to the assigned out...

Page 16: ...abled using the set upload enable yes command on the console interface To upgrade the iBootBar download the latest version of the firmware and upgrade utility from the Dataprobe website http Dataprobe...

Page 17: ...M C14 8 x C13 I S M iBP 2C10 2 x C14 8 x C13 I S iBP 2C10 M 2 x C14 8 x C13 I S M iBP C20 C20 8 x C13 I S iBP C20 M C20 8 x C13 I S M iBP 2C20 2 x C20 8 x C13 I S iBP 2C20 M 2 x C20 8 x C13 I S M Key...

Page 18: ...n for help This device complies with Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must ac...

Page 19: ...current country setting Note Use of the wrong countrycode violates local laws and the warranty of this product Country countrycode Argentina 07 Australia 09 Austria 253 Belgium 253 Canada 181 China 1...

Page 20: ...r32 delayTime 2 TB snmpManagerTable 1 TE snmpManagerEntry 1 RO Integer32 snmpManagerIndex 2 RW DisplayString snmpManagerIPAddress 3 RW INTEGER Enum snmpManagerEnable 3 TB outletTable 1 TE outletEntry...

Page 21: ...Dataprobe Technical Service at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purcha...

Reviews: