ITEM DESCRIPTION
WIRELESS ETHERNET
Controls the communications settings for the wireless Ethernet network interface, where:
IP DISCOVERY
Sets the address discovery method, where:
USE STATIC
ADDRESSES
The stored static IP, Subnet Mask, and / or Gateway Address will be used.
USE DHCP
The card broadcasts over the network using DHCP protocol to receive addresses from the
responsible server at startup. Manual modifications to IP Address, Subnet Mask, or Gateway Address
are not allowed; and, if no server is found, the specified static value will be used. (Default Setting)
A server assigned IP address takes precedence over any static IP address
stored in the interface.
USE BOOTP
The card broadcasts over the network using BOOTP protocol to receive addresses from the
responsible server at startup. Manual modifications to IP Address, Subnet Mask, or Gateway Address
are not allowed; and, if no server is found, the specified static value will be used. (Default Setting
)
A server assigned IP address takes precedence over any static IP address
stored in the interface.
STATIC IP
ADDRESS
Specifies the static IP Address of the interface in the standard octet format.
STATIC SUBNET
MASK
Specifies the static Subnet assigned to the interface, for example:255.255.255.000.
STATIC
GATEWAY
Specifies the Gateway Address the interface will use, for example:192.168.10.1
BLUETOOTH
Controls the communications settings for the Bluetooth network interface, where:
DISCOVERABLE
Yes/No; Determines whether other Bluetooth devices in range can detect the printer.
CONNECTABLE
Yes/No; Determines whether other Bluetooth devices in range can connect to the printer.
BONDABLE
Yes/No; Determines whether other Bluetooth devices in range can create a “bondable” connection
with the printer
AUTHENTICATION
REQUIRED
Yes/No; Determines whether passkey is required to the printer.
ENCRYPTION
Yes/No; Determines whether encryption is used during data transfer to the printer.
INACTIVE
DISCONNECT
TIME
(0-65535 in seconds); Default: 60
Set the amount of time (
in seconds
) in which the current connection will remain open when no
activity is present.
POWER DOWN
TIME
(0-65535 in seconds); Default: 60
Set the amount of time (
in seconds
) in which the Bluetooth module will remain on when no activity
is present.
GENERAL NETWORK
Controls general communication parameters, where:
SNMP ENABLE
Sets SNMP
NO (Default
Setting)
YES
TELNET ENABLE
Enable/Disable Telnet protocol
NO (Default
Setting)
YES
FTP SERVER
ENABLE
Enable/Disable FTP protocol
NO (Default
Setting)
YES
HTTP SERVER
ENABLE
Enable/Disable FTP protocol
NO
YES (Default
Setting)
LPD PRINT
ENABLE
Enable/Disable LPD protocol
NO
YES (Default
Setting)
TCP PRINT
ENABLE
Enable/Disable TCP protocol
NO
YES (Default
Setting)
NETCENTER
ENABLE
Enable/Disable Netcenter compatibility
NO (Default
Setting)
YES
GRATUITOUS ARP
Sets time interval for ARP transmission packets, where:
(0-100 minutes); Default is 0
NETWORK REPORT Print or view on screen the printers network information.
Summary of Contents for E-Class Mark III Professional+
Page 1: ...Operator s Manual Professional and Professional Models Professional Professional ...
Page 2: ......
Page 26: ...20 Chapter 2 Printer Setup ...
Page 68: ...62 Chapter 5 Maintenance Adjustments ...
Page 72: ...66 Chapter 6 Troubleshooting ...
Page 76: ...70 Appendix A Specifications ...
Page 84: ...78 Appendix B WLAN LAN Setup ...
Page 86: ...80 Appendix C Bluetooth Setup ...
Page 92: ......