DATAMARS
R-IN 1300 MC User Manual – Rev
6.0
14 (50)
This command accepts a minimum of 2 and a maximum of 20
parameters, between 1 and 7 each.
Example:
*am321356 antennas 3, 2,1,3,5 and 6 in the given sequence.
Always enter command *sm1
after
issuing an *am
command
*ta[_]
Number of reading cycles per selected antenna.
This command accepts a minimum of 2 and a maximum of 20
parameters, between 1 and 9 each.
Example: if antennas 1, 2 and 3 have been selected with
*am123
and
*ta468
The reader will read four times on antenna 1, six times on
antenna 3 and eight times on antenna 3.
The number of parameters of *ta has to be always the same
as the number of parameters of *am
Always enter command *sm1
after
issuing an *ta command
*oa[_]
Digital output per selected antenna. This command accepts a
minimum of 2 and a maximum of 20 parameters, between 0 and
8 each.
Example: if antennas 1, 2 and 3 have been selected with
*am123
and
*oa678
The reader will activate output 6 when antenna 1 is selected,
output 7 when antenna 2 is selected and output 8 when antenna
3 is selected.
Output channels 0 to 8 correspond to the following open collector
outputs on the I/O connector:
0
No output selected
1
Internal relays selected
2
Digital output A1
3
Digital output A2
4
Digital output A3
5
Digital output A4
6
Digital output B1
7
Digital output B2
8
Digital output B3
The number of parameters of *oa has to be always the
same as the number of parameters of *am
Always enter command *sm1
after
issuing an *oa command
*pg[_]
This command applies specific tunnel antenna switching
algorithms.
*pg0: Cyclic
*pg1: Progressive
*pg2: Cyclic/Progressive
If you are not using a tunnel antenna, use parameter *pg0