DATAMARS
R-IN 1300 MC User Manual – Rev
6.0
11 (50)
*at2
Tunnel Antenna (Cyclic switching scheme)
*at3
Tunnel Antenna (Progressive switching scheme)
*at4
Tunnel Antenna (Cyclic/Progressive switching scheme)
*at5
Bin Antenna (5W Power and quite mode set as default)
Quiet mode set as default for Tunnel Antenna
See the user manual of the specific antenna for further details.
*ha[_]
Antenna Enumeration:
When enabled, each UID will include a number indicating which
channel (antenna) read it.
Example:
3 E00123456789ABCD
Antenna 3 has read the UID E00123456789ABCD
*ha0: disable antenna enumeration (default)
*ha1: enable antenna enumeration
*an[_]
HF antenna select:
Selects the channel to which the antenna is connected (if the
reader is Multi-channel).
*an1: select HF antenna 1 (default)
*an2: select HF antenna 2
*an3: select HF antenna 3
*an4: select HF antenna 4
*an5: select HF antenna 5
*an6: select HF antenna 6
*an7: select Splitter antenna 7: corresponds to the splitter: the
two channels marked with “Splitter 1” an “Splitter2” (on the front-
panel of the reader) are activated at the same time each one
using the half of the power
This command is valid only with antenna types 0 and 1
(*at0 and *at1)
*cb[_]
Combo Mode:
This mode allows connecting a secondary reader to the “R-
IN1300 MC”.
*cb0:
Combo mode disabled (default)
*cb1:
Multiplexed output enabled Combo mode (Digital Output
A1)
*cb2:
Multiplexed RS-232 enabled Combo Mode (R-IN7500)
*cb3:
Continuous Combo Mode
*cb4:
the same as *cb1 but for generic readers
*cb5
the same as *cb3 but for generic readers
*cb6
the same as *cb3 but for R-IN9000 readers
When any combo mode is enabled, an R-IN7500 reader can be
configured by sending commands to the “R-IN1300 MC”, with the
standard R-IN7500 syntax.
*tc[_]
Secondary reader multiplexed reading time * 20ms:
Example:
*tc[120]: 120 * 20 ms = 2400 ms = 2.4 s
Maximum allowed parameter: 200 (4s)
*os[_]
Indicates which I/O channel is to be used to drive the LF-Reader
if combo-mode is set.
Output line for combo mode.