DATAMAN S4 MANUAL
FUNC SETUP =
Advanced<$&FUNCSETUP>
63
If you lend your S4 to a colleague, it is wise
precaution to make
a LIBRARY ROM with your own
configurationfirst. Then, when you get
you S4 back, you can restore all your own
preferences (if you do get
it back).
FUNC SETUP =
Advanced<$&FUNCSETUP>
@COMPUTER TEXT = >> ADVANCED
SETUP<R>
Shutdown Time 1E<R>
High Tone 98<R>
Low Tone AC<R>
Busy Tone 50<R>
Max Batt Temp AA<R>
Min Batt Temp 64<R>
Charge Time 0B<R>
Discharge Time 1C<R>
Deep Discharge 40<R>
Norm Discharge C0<R>
To adjust advanced SETUP parameters you will
need to convert numbers
from decimal to hexadecimal.
@BULLET = Shutdown Time 1E = 30 minutes
The audible tones that S4 makes can be changed
in pitch, or removed
altogether by setting to 00.
@BULLET = High Tone 98 = 1520 hz
@BULLET = Low Tone AC =1720 hz