SG BODY REFLECTOR MUTING
19
3.2.4 Active and passive orientation
The two units shall be assembled parallel each other, and looking at the references on the aluminium profile.
The configurations shown in Figure 20 must be avoided:
Figure 20
3.2.5 Precautions to respect during the use of deviating mirrors
The operator must observe the following precautions when using the deviating mirrors:
•
The alignment of the active unit can become a very critical operation when
deviating mirrors are used. Even a very small angular displacement of the mirror
is enough to lose alignment. The SG-LP laser pointer accessory can be used to
avoid this problem.
•
The presence of dust or dirt on the reflecting surface of the mirror causes a
drastic reduction in the range.
3.2.6 Controls after first installation
•
The control operations to carry-out after the first installation and before machine start-up
are listed hereinafter. The controls must be carried-out by qualified personnel, either
directly or under the strict supervision of the person in charge of machinery Safety.
Verify that:
•
ESPE remains in SAFE state (
) intercepting the beams along the protected area using
the specific test piece (TP-40, TP-50, TP-90), following the Figure 21 scheme.
Figure 21
NO
NO