2.6 RESOLUTION
The resolution of the device is the minimum dimension that an opaque object must have in order to obscure
at least one of the beams that constitute the sensitive area.
The resolution strictly depends on the part of the body to be protected.
The following table shows the values of the optic interaxis (
I
), the resolution (
R
) and the optic diameter (
d
), of
the safety light curtains.
Model
Optic
interaxis
(
I
) [mm]
N.
optics
Resolution
(
R
) [mm]
Lens diameter
(
d
) [mm]
ESPE Type
SG4-RB2-050-OO-W
SG4-RB2L-050-OO-W
SG4-RB2T-050-OO-W
SG4-RB2-050-OO-N
500
2
519,75
19,75
Body protection
Type 4
SG4-RB3-080-OO-W
SG4-RB3L-080-OO-W
SG4-RB3T-080-OO-W
SG4-RB3-080-OO-N
380
3
399,75
19,75
Body protection
Type 4
SG4-RB4-090-OO-W
SG4-RB4-090-OO-N
300
4
319,75
19,75
Body protection
Type 4
SG4-RB4-120-OO-W
SG4-RB4-090-OO-N
400
4
419,75
19,75
Body protection
Type 4
As shown in Figure 1, the resolution depends only on the geometrical characteristics of the lenses, diameter
and distance between centers, and is independent from any environmental and operating conditions of the
safety light curtain.
ACTIVE
PASSIVE
R
d
I
Figure 1
The resolution value is obtained applying the following formula:
R = I + d
Where:
I
=
Distance between two adjacent optics
d
=
Lens diameter